Operation; Panel - FineTek EE310 Operation Manual

Electromechanical level measuring system
Table of Contents

Advertisement

7. Operation

7.1. Panel

AC type
① Power switch: On-site operation, maintenance, and power off when needed.
② Power terminal: power input 100~240Vac, 50/60Hz or 24Vdc (please confirm the order
specification)
③ Heater terminal: connected to the internal antifreeze heater.
④ Power system terminal: connect with DC power supply.
⑤ Motor Power terminal: connect to the motor DC24V
⑥ Display: status display, height indication, fault indication, parameter setting
⑦ Indicator light:
(Green) → Power indicator: Lights up when power is on, and the light is turned off when the power
is disconnected.
(Yellow)→ Operation indicator: Lights up during the measurement (up and down), and lights off
when measurement ends.
(Red)→ Fault indication: Lights up on wire breakage, buried, knot, over-heat occurs, and lights off
when troubleshooting is finished.
⑧ Button:
Ent/Run: Measured value display mode = start the measuring.
Menu mode = enter into the next menu / confirm to save.
Left: Measured value display mode = enter into the menu.
Menu mode = scroll down the menu.
Number mode = cursor moves to left.
Up: The number on the cursor increases.
Exit: Return to the previous menu.
⑨ Input/output terminal: Transistor pulse output/external trigger/fill-in protection.
⑩ Relay output terminal: Relay 1~4.
⑪ Connector socket: wiring with Sensor connector
⑫ Connector socket: wiring with Sensor connector
⑬ Connector socket: wiring with the wireless module (if any) connector
DC type
12

Advertisement

Table of Contents
loading

Table of Contents