Device description

7.1

Views

Figure 1: Front view
7.2

Indicator elements

The operating status of the device and the status of the analog inputs are shown by
colored status LEDs.
7.2.1

Operating status

LED
L1: green
L2: yellow
L3: white
L4: red
Important note
When the LED L4 indicates a failure, please contact the iba Support.
12
Manual
Fixing screws
1
2
Operating status indicators L1... L4
3
Status LEDs L26 to L33 of the ICP inputs 00...07
4
Connector X1 for ICP inputs 00...03
5
Connector X1 for ICP inputs 04...07
Status
Description
Flashing / On
Device is working
Off
Device is not working (switched off)
On
Access to the backplane bus
-
-
Off
Normal status, no faults
Flashing
Device failure
Issue 1.7