3. Control Terminals

External braking
BU-
unit (optional)
R1K
Strip X1
F unction
Programmable / configurable analog differential input. Signal: terminal 1.
1
Analog input 1
Reference point: terminal 2. Default setting: Ramp ref 1
2
Programmable / configurable analog differential input. Signal: terminal 3.
3
Analog input 2
Reference point: terminal 4. Default setting: none
4
Programmable / configurable analog differential input. Signal: terminal 5.
5
Analog input 3
6
Reference point: terminal 6. Default setting: none. (1)
7
Reference voltage +10V; Reference point: terminal 9
+10VDC
8
Reference voltage -10V ; Reference point: terminal 9
-10VDC
9
Internal 0V and reference point for 10V
0V
12
Enable drive
Drive enable: 0V or open; drive disabled; +15...+30V: Drive enabled
13
Drive start command: 0V or open: No start; +15...+30V: Start
Start
14
Fast stop
OV or open: Fast stop. +15...+30V; No Fast stop.
15
OV or open: External fault. +15...+30V; No External fault
External fault
16
Reference point for digital inputs and outputs, term.12...15, 36...39, 41...42
COMD I/O
18
Reference point for +24V OUT supply, terminal 19
0V24
19
+24V supply output. Reference points: terminals 18 or 27 or 28
+24VDC
Analog output
21
Program. analog output; def. setting: Motor speed. Ref. point: term. 22
1
22
0V
Internal 0V and reference point for terminals 21 and 23
Analog output
23
Program. analog output; def. setting: Motor current. Ref. point: term. 22
2
BU comm.
26
VeCon controlled BU-... braking units command. Ref. point: term. 27.
output
27
0V24
Reference point for BU-...command ,terminal 26
28
RESERVED
RESERVED
29
36
Digital input1
Digital input2
37
Programmable digital input; default setting: none
Digital input3
38
Digital input4
39
Digital output
41
1
Programmable digital output; default setting: none
Digitaloutput
42
2
Supply DO
Supply input for digital outputs on terminals 41/42. Ref. point: term.16.
46
78
Motor PTC
Motor PTC sensing for overtemperature (cutoff R1k if used)
79
Strip X2
F unction
80
OK relay
Potential-relay contact OK relay (closed=OK)
contact
82
83
R elay 2
Potential-relay contact configurable (relay2).
contact
Default: open 0 drive stopped
85
max
10V
@ 0.25mA
(20 mA when
current ref
input)
+10V/10 mA
-10V/10 mA
-
+30V
3.2 mA@15V
5 mA@24V
6.4 mA@30V
-
-
+22...28V
120 mA@24V
10V/5 mA
-
10V/5 mA
+28V/15 mA
-
-
+30V
3.2 mA@15V
5 mA@24V
6.4 mA@30V
+30V/40 mA
+30V/80 mA
1.5mA
max curr.
250VAC
1A, AC11
250VAC
1A, AC11