Furuno FA-100 Installation Manual page 15

Uais transponder
Hide thumbs Also See for FA-100:
Table of Contents

Advertisement

Flush mounting
Optional flush mount kit A or B is required for flush mounting. For mounting
dimensions, refer to the outline drawing at the back of this manual.
Flush mount kit A:
Name
1
Cosmetic panel
2
+Tapping screw
1. Cut out a hole in the mounting location, referring to the outline drawing.
2. Remove two hex bolts to dismount the mounting base.
3. Remove six hex bolts from the bottom of the transponder unit to dismount the
mounting pedestal.
4. Set the transponder unit to the cosmetic panel and fix them with six hex bolts.
5. Set the assembly (transponder unit and cosmetic panel) to the hole and fix it
with four tapping screws (5x25).
Flush mount kit B:
Name
1
Mounting bracket
2
Hex bolt
3
Hex nut
4
Flat washer
5
Spring washer
1. Cut out a hole in the mounting location, referring to the outline drawing.
2. Dismount the mounting base and mounting pedestal from the transponder unit.
3. Set the transponder unit to the hole. Using six hex bolts, attach the mounting
bracket at the bottom of the transponder unit from the rear of the flush mounting
panel.
4. Fix with six sets of hex bolt, nut, flat washers and spring washers from the rear
of the flush mounting panel.
Type OP24-1
Code no. 005-950-740
24-003-2811
5x25
Type OP24-2
Code no. 005-950-750
24-003-2821
M5x25
M5
M5
M5
Type
Code no.
100-299-540
000-802-082
Type
Code no.
100-299-550
000-862-125
000-863-108
000-864-128
000-864-258
Qty
1
4
Qty
1
6
6
6
6
9

Hide quick links: