Mitsubishi Electric FR-CC2-P Instruction Manual page 132

Table of Contents

Advertisement

5.8
Parameter clear / all parameter clear
POINT
POINT
• Set "1" to Pr.CLR Parameter clear, ALL.CL All parameter clear to initialize all parameters. (Parameters cannot be cleared
when Pr.77 Parameter write selection = "1".)
• Terminal function selection parameters are not cleared with Pr.CL.
• Refer to the parameter list on
Screen at power-ON
1.
The monitor display appears.
Parameter setting mode
2.
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Selecting the parameter number
To perform a parameter clear, turn
3.
. "
" (initial value) appears.
Parameter clear
Turn
to change the set value to "
alternately after parameters are cleared.
4.
Setting
value
Pr.CLR Parameter clear
0
Initial display (Parameters are not cleared.)
Returns parameters excluding terminal function
1
selection parameters, etc. to their initial values.
page 170
for availability of parameter clear and all parameter clear for each parameter.
Operation
to
". Press
Turn
to read another parameter.
Press
to show the setting again.
Press
twice to show the next parameter.
Description
Parameter clear / all parameter clear
, and to perform all parameter clear, turn it to
to enter the setting. "
" and "
ALL.CL All parameter clear
Returns all parameters which can be cleared
including terminal function selection
parameters to their initial values.
and press
" (
) blink
131
PARAMETER