SECTION 3 ADJUSTMENTS

1. 3. Adjusted data transfer

1. 3. 1. Equipment to be used
1. Computer : Use it for the transfer of backup data.
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Service Software : "ServiceVZ570" Service software is downloaded from the projector service homepage.
1. 3. 2. Connection preparations
1. Connect the serial terminals on the projector and the
PC by using a communication cable.
1. 3. 3. Backup the data (before board re-
placing)
1. Set the projector to "Normal-Standby" mode (ON(G)/STANDBY(R) indicator is lighting in red).
2. Start up the software "ServiceVZ570.exe" with a PC.
3. Select language and click the [OK] button.
4. 1) Choose the available serial port number on your PC.
2) Choose a model number.
3) Click the [Data] button.
5. 1) Click the [ Reception ] button of Micom data.
2) Select the save place and click the [ Save(S) ] button.
3) When the progress bar reaches the right-side end, the save of data is completion.
4) Save the Gamma data in the same procedure of 1-3.
5) Save the Uniformity data in the same procedure of 1-3.
j
k
j
l
Projector Connection terminals
D-Sub 9p (Female)
D-Sub 9p (Male)
File name
Data type
Micom Data
M_Data.dat
Gamm Data
G_Data.dat
Unifomity data
E_Data.dat
ADJ-6
Communication cable (straight)
* Do not rename the data file.