SECTION 1 SERVICE INFORMATION

6. 2. Lamp log data acquisition method

6. 2. 1. Equipment to be used
1. Computer : Use it for getting the lamp log data.
2. Communication cable : D-sub 9pin (male/female RS-232C straight)
3. Service Software : "ServiceVZ570" Service software is downloaded from the projector service homepage.
6. 2. 2. Connection preparations
1. Connect the serial terminals on the projector and the
PC by using a communication cable.
6. 2. 3. Acquisition of log data
1. Set the projector to "Normal-Standby" mode (ON(G)/
STANDBY(R) indicator is lighting in red).
2. Start up the software "ServiceVZ570.exe" with a PC.
3. Select language and click the [OK] button.
4. 1) Choose the available serial port number on your PC.
2) Choose a model number.
3) Click the [Data] button.
5. 1) Click the [Log Display] button. The log dislay window will appear.
2) Click [Lamp Log receive] button. The log data will appear on the window.
j
k
l
j
Projector Connection terminals
D-Sub 9p (Female)
D-Sub 9p (Male)
INF-24
Computer
Communication cable (straight)
k