Dispenser calibration

Dispenser calibration is used to measure the throughput of the indi-
vidual dispensing pumps.
Press and hold multifunction button 2 and switch the machine on
with  "Power on".
Dispenser calibration
Dispenser pump 1
Dispenser pump 2
Options:
Dispensing pump 1
-
Select a dispensing pump.
When a dispensing pump is selected, the following will appear in the
display:
Dispenser calibration
V:
100 ml
Tip: The dispensing quantity can be set from 0 to 9999 ml in 1 ml in-
crements.
Press the multifunction button 
The dispensing hose will fill up.
Stop the process by pressing the
Run the hose of the dispensing pump upwards into a measuring
vessel.
Hold the entire measuring vessel above the dispensing pump while
doing this.
 Irritant detergents.
Skin and eye irritation.
Avoid contact with skin and eyes, wear protective clothing.
Return to the main menu by pressing the  "Back" button.