6.1 Mounting the connector
To achieve the protection rating indicated in the data sheet, the following has to be observed:
u Use IO-Link cable with IP class.
u Connect the connector with the unit. The arrow indicates the position of the coding.
u Tighten the coupling nut.
Minimum tightening torque: 0.6 Nm (tightening by hand)
Maximum tightening torque: 1.5 Nm (using a torque wrench).
If used in harsh environments:
w Further tighten the coupling nut by another notch using a torque wrench (across the flats 14).
6.2 Removing the connector
u Press the connector against the unit and simultaneously loosen the coupling nut.
6.3 Cable length
With IO-Link communication: 20 m on the master side
u Provide all input and output side cables with a strain relief approx. 200 mm behind the connectors.