Contents 1 Preliminary note ....................4 1.1 Symbols used ....................4 1.2 Warnings used ....................4 2 Safety instructions ....................5 3 Functions and features ..................6 3.1 Block diagram ....................6 3.2 General application and functionality .............6 3.3 Application as an IO-Link device ..............7 3.3.1 General information ................7 3.3.2 IO Device Description (IODD) ..............7 4 Operating and display elements ................8 4.1 LEDs ......................8...
Page 3
13.1 Maintenance ....................15 13.2 Cleaning the housing surface ..............15 13.3 Repair ......................15 13.4 Disposal .....................15 This document is the original instructions.
1 Preliminary note Technical data, approvals, accessories and further information at www.ifm.com. 1.1 Symbols used ► Instructions > Reaction, result […] Designation of keys, buttons or indications → Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note.
2 Safety instructions • The device described is a subcomponent for integration into a system. The manufacturer is responsible for the safety of the system. The system manufacturer undertakes to perform a risk assessment and to create a documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
3 Functions and features 3.1 Block diagram OUT1 (analogue) IO-Link C/Q DP1223 OUT2 (analogue) Inputs/outputs of the device 3.2 General application and functionality The device is used for the control of a connected actuator or another device with analogue input (0...10 V). It is not suited for environments with particular requirements on mechanical stability (e.g.
The IO-Link interface allows direct access to the process and diagnostic data and enables setting of the parameters of the unit during operation. You will find further information about IO-Link and all necessary information about the required IO-Link hardware and software at: www.ifm.com/gb/io-link. Fieldbus 0...10 V 24 V DC...
4 Operating and display elements 1: LEDs 4.1 LEDs Colour Status Description OUT1 yellow Analogue value in the standard range: 0...100 % (0...10 V) flashing (2 Hz) Analogue value in the range: 100...110 % (10...11 V) flashing (5 Hz) Short circuit or overload at the output Power green Voltage supply OK.
If required, the device can be fixed with a mounting clip. Mounting clip (fasten with M4 screw or Mounting clip with display attached cable ties) The mounting clip is not supplied with the device. More information about the available accessories at: www.ifm.com...
6 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to SELV, PELV. ► Protected circuits Potential M12 connector Circuit breaker ①...
Page 11
Pin 4-pole M12 make connector ① L+ / supply voltage not used L- / supply voltage C/Q IO-Link Pin 5-pole M12 female connector ② 0...10 V analogue output 2 0...10 V analogue output 1 not used 1: IO-Link side 2: Actuator side The device must not be externally supplied via the 5-pole M12 output socket ②.
6.1 Maximum length of the connection cables With IO-Link communication on the master side: 20 m. All cables must be provided with a strain relief approx. 200 mm behind the connectors. 7 Operation The device provides the output signals according to the process data set via IO- Link.
10 Scale drawing P_MZ_e200_0100 Original Scale Drawing (MTD) M12 x 1 M12 x 1 Dimensions [mm] EPS Source Product Scale Drawing Frame Size: 80 mm x 49,5 mm M12 x 1 M12 x 1...
11 Technical data Operating voltage DC 18...30 Nominal voltage DC Current consumption [mA] Number of analogue outputs Analogue output (voltage) 0...10 Extended voltage range 0...11 Min. load resistor [Ω] 2000 Accuracy [% FS] 0.25 Protection rating IP 67* Degree of soiling Ambient temperature [°C] -25…70...
11.2 Approvals/standards EU declarations of conformity, approvals etc. can be downloaded at: www.ifm.com 12 Troubleshooting Status Error Troubleshooting flashing (5 Short circuit or Check/correct connection cables and overload at the output connections at the output (→ 6). Power flashing (5 Supply voltage too low.