  • Page 1 Operating instructions Passive power distributor AC5050 AC5051...
  • Page 2: Table Of Contents

    AC5050 AC5051 Passive power distributor Contents Preliminary note .............
  • Page 3: Preliminary Note

    Passive power distributor AC5050 AC5051 1 Preliminary note You will find instructions, technical data, approvals, accessories and further information using the QR code on the unit / packaging or at www.ifm.com. 1.1 Symbols used Requirement Instructions Reaction, result [...] Designation of keys, buttons or indications...
  • Page 4: Safety Instructions

    AC5050 AC5051 Passive power distributor 2 Safety instructions • The unit described is a subcomponent for integration into a system. – The system architect is responsible for the safety of the system. The system architect undertakes to perform a risk assessment and to create documentation in accordance with legal and normative requirements to be provided to the operator and user of the system.
  • Page 5: Intended Use

    Each supply connection (AS-i operation: AS-i / AUX; IO-Link operation: US / UA) has overcurrent detection (no shutdown). • AC5050: 4-port power distributor • AC5051: 8-port power distributor The device is designed for use without a control cabinet (indoor use).
  • Page 6: Installation

    AC5050 AC5051 Passive power distributor 4 Installation 4.1 Install device u Disconnect the power to the machine during installation. u Use a flat mounting surface for installation. u Fix the unit to the mounting surface using 2 M5 mounting screws and washers, max. tightening...
  • Page 7: Electrical Connection

    Passive power distributor AC5050 AC5051 5 Electrical connection The device must be connected by a qualified electrician. Observe the national and international regulations for the installation of electrical equipment. Disconnect power. Voltage supply according to SELV / PELV. The IP rating of the overall system depends on the protection ratings of the individual devices, the applied connection elements and the corresponding protective caps.
  • Page 8: Voltage Supply / Fuse

    AC5050 AC5051 Passive power distributor Voltage supply Power OUT 1…4 (AC5050) / 1…8 (AC5051) (voltage output) IO-Link operation M12 socket AS-i operation (4/5 poles, A-coded) 1: + 24 V DC (US) 1: AS-i + 2: GND (UA) 2: AUX -...
  • Page 9: Operating And Display Elements

    Passive power distributor AC5050 AC5051 6 Operating and display elements LED FLT UA ⁄ AUX LED FLT US ⁄ AS-i LED US ⁄ AS-i LED UA ⁄ AUX Fig. 1: LED assignment LED US / AS-i green: US / AS-i voltage supply ok...
  • Page 10: Scale Drawing

    AC5050 AC5051 Passive power distributor 7 Scale drawing 59,3 38,4 Fig. 2: AC5050: 4-port power distributor 59,3 38,4 Fig. 3: AC5051: 8-port power distributor...
  • Page 11: Maintenance, Repair And Disposal

    Passive power distributor AC5050 AC5051 8 Maintenance, repair and disposal The operation of the unit is maintenance-free. Only the manufacturer is allowed to repair the unit. u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations.