Microlife BP A200 AFIB Manual page 3

Oscillometric blood pressure monitor
Hide thumbs Also See for BP A200 AFIB:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 3
Microlife BP A200 AFIB
1 ON/OFF button
2 M-button (memory)
3 Display
4 Cuff Socket
5 Time Button
6 Cuff
7 Cuff Connector
8 Mains Adapter Socket
9 USB Port
AT Battery Compartment
AK AFIB/MAM Switch
Display
AL Date/Time
AM Systolic Value
AN Diastolic Value
AO Pulse Rate
AP Atrial Fibrillation Indicator (AFIB)
AQ MAM Interval Time
AR Battery Display
AS Stored Value
BT Pulse Indicator
BK AFIB/MAM Mode
Read the instructions for use
Type BF applied part
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
Keep dry
Temperature limitation
Serial number
SN N
BP A200 AFIB
Catalogue number
Manufacturer
Date of manufacture
Protection against solid foreign objects and harmful effects
IP20
due to the ingress of water
A mark of compliance with technical regulations
CE Marking of Conformity
Intended use:
This oscillometric blood pressure monitor is intended for measuring
non-invasive blood pressure in people aged 12 years or older.
It is clinically validated in patients with hypertension, hypotension,
diabetes, pregnancy, pre-eclampsia, atherosclerosis, end-stage
renal disease, obesity and the elderly.
The device can detect an irregular pulse suggestive of Atrial Fibril-
lation (AF). Please note that the device is not intended to diagnose
AF. A diagnosis of AF can only be confirmed by ECG. The patient
is advised to see a physician.
Dear Customer,
This device was developed in collaboration with physicians and
clinical tests carried out prove its measurement accuracy to be of
a very high standard.*
Microlife AFIB detection is the world's leading digital blood pres-
sure measurement technology for the detection of atrial fibrillation
(AF) and arterial hypertension. These are the two top risk factors
of getting a stroke or heart disease. It is important to detect AF and
hypertension at an early stage, even though you may not experi-
ence any symptoms. AF screening in general and thus also with
the Microlife AFIB algorithm, is recommended for people of 65
years and older. The AFIB algorithm indicates that atrial fibrillation
may be present. For this reason, it is recommended that you visit
your doctor when the device gives an AFIB signal during your
blood pressure measurement. The AFIB algorithm of Microlife has
been clinically investigated by several prominent clinical investiga-
tors and showed that the device detects patients with AFIB at a
1,2
certainty of 97-100%.
EN
EN