Manual for:
VGE Pro UV Control Monitor+ 400/420/600 and VGE Pro UV Control Monitor+ 140/200
'I
'
out
current output
X10
1. signal
2. signal ground
'temp'
temperature sensor
terminal
X11
1. KTY (-) sensor signal
2. KTY (+) sensor signal
3. cable shield
'modbus'
RS485 terminal
X12
1. signal A (+)
2. signal B (-)
3. ground
'switch 2'
switching input 2
terminal
X13
1. contact A / 12V DC supply
2. contact B
3. ground for supply
'frontend'
control panel terminal
X14
RJ45 western plug
'switch 1'
switching input 1
terminal
X15
1. contact A
2. contact B
'interlock 1'
X18
1. contact A
2. contact B
02/2017
4...20mA output signal corresponding to UV value
active signal output, galvanically isolated
output voltage: max. 15V DC
max. load: 450Ω
interface for analog temperature sensor
types: KTY110, KTY210 (type selection via menu)
including ground connection for sensor cable shield
Note:
The sensor cable shield must be open on the sensor plug connector,
the sensor shield must not be connected externally to ground potential.
RS485 interface to superiour control unit
galvanically isolated
including ground connection for cable shield
no internal termination or biasing
switching input including 12V DC supply for external module
function depends on operating software
holding current: 1mA at loop resistance 0Ω
loop resistance: max. 1kΩ
12V DC supply voltage:
output power: max. 1W
not sustained short circuit proof
(short circuit current: max 250mA, max. 10s)
Note: The overall power consumption of 'switch 2', 'digisens' and 'current input I
exceed 1.5W, otherwhile the unit will be switched off automatically.
interface to control panel
connection using CAT5e patch cable
includes power supply and data connection
Note: No Ethernet function implemented. Do not connect to any Ethernet periphery.
switching input 100...250V AC for remote start/stop
100...250V AC have to be applied to contacts A+B for remote start,
if remote function is enabled via menu
power-on threshold: min. 100V AC
switch-on/off hysteresis: typ. 15V AC
internal resistance: 180kΩ
hardware-interlock (affects the power supply of the mains relay)
closing contacts A+B enables ballast function and powers ballast section
supply by base unit
holding current: 5...15mA DC
open-loop voltage: max. 30V DC
max. cablelength per interlock-loop: 29.9m;
for cablelength larger then 2.90m use a ferrite cable core type WÜRTH 74270053 near
the terminal ends, wind both cable ends 1x through the cable core.
Safety note: The mains relay operation is additionally controlled by a safety circuit. If the mains
relay deactivation fails (e.g. caused by sticking contacts) lamps are switched off and the ballast
function is deactivated and locked. Warning: The ballast section remains on mains potential in
this case.