3.2.11 More Settings; Main Menu; Heating Settings - Bosch Compress 7000 AWM/AWMS 5-17 User Manual

Air/water heat pump
Table of Contents

Advertisement

Operation

3.2.11 More settings

Setting the time and date
If the user interface has been disconnected from the power supply for a
prolonged period, the date and time must be set:
▶ Restore the power supply.
The user interface displays the setting for the date.
▶ Set the day, month and year respectively and confirm.
▶ Confirm Next.
The user interface displays the setting for the time.
▶ Set the hours and minutes respectively and confirm.
▶ Confirm Next.
No other settings are required for recommissioning.
Switching the key block on/off
To switch the key block on or off:
▶ Press the selector and DHW key simultaneously until the key symbol
in the display appears/disappears.
Setting up the favourite functions
The fav key gives direct access to often used functions for heating circuit
1. Press the key once to open the menu.
To adapt the list of favourites in the menu:
▶ Press and hold the fav key until the configuration menu is displayed.
▶ Turn and press the selector to select a function (Yes) or to cancel the
selection (No).
▶ Press the d key to close the menu.
12
0010003250.002
0010003251.001
6 720 811 136-15.1O
3.3

Main menu

Depending on the heating appliance and how the user interface is used,
not all menu items will be available for selection; see overview of main
menu at the end of this document.
3.3.1

Heating settings

Menu: Heating
Menu item
Description
Op. mode
Select the heating operating mode: optimised or
based on time program.
Temperature
Temperatures for the levels [Heating], [Setback ]or
settings
[Optimised operation] can be set in this menu.
 see Tab. 5
Time program
 see Tab. 6
Summer/winter
changeover
 see Tab. 7
DHW alternating
operation
Table 3 Heating settings
Menu: Heating/Cooling
Menu item
Description
Op. mode
Select the heating operating mode: optimised or
based on time program.
Temperature
Temperatures for the levels [Heating], [Setback],
settings
[Optimised operation] or [Cooling] can be set in this
menu.
 see Tab. 5
Time program
 see Tab. 6
Summer/winter
changeover
 see Tab. 7
DHW alternating
operation
Table 4 Heating settings
Adapting the Time program for the automatic mode
Menu: Time program
Menu item
Description
Activate time
Activating automatic mode triggers control of the
program
room temperature according to the settings in the
selected time program [My time program 1] or [My
time program 2].
My time program
2 switching times can be set for each day or group of
1
days. One of the two operating modes (or a
temperature) can be assigned to each switching
time in automatic mode. The minimum duration of a
time slot between two switching times is
15 minutes.
Resetting prog.
The default setting for [My time program 1] can be
restored here.
 See [My time program 1]
My time program
2
Resetting prog.
The default setting for [My time program 2] can be
restored here.
Rename time
The names of the time programs can be changed in
prog.
the same way as the names of the heating circuits.
This helps to select the correct time program,
e.g. "family" or "night shift".
Table 5 Time program settings for heating