1 DIAGNOSTIC TROUBLESHOOTING PROCEDURES
SPN
FMI
Sub-section
3482
3
AFTFSV (page 205)
3482
4
AFTFSV (page 205)
3509
3
VREF (page 2025)
3509
4
VREF (page 2025)
3510
3
VREF (page 2025)
3510
4
VREF (page 2025)
3511
3
VREF (page 2025)
3511
4
VREF (page 2025)
3521
11
DEFTLT (page 746)
3556
0
AFTFP2 (page 257)
3556
1
AFTFP2 (page 257)
3556
7
AFTFP2 (page 257)
3610
2
DPFDP / DPFOP (page 844)
3610
3
DPFDP / DPFOP (page 844)
3610
4
DPFDP / DPFOP (page 844)
3659
4
INJ (page 1365)
3659
5
INJ (page 1365)
3660
4
INJ (page 1365)
3660
5
INJ (page 1365)
3661
4
INJ (page 1365)
3661
5
INJ (page 1365)
3662
4
INJ (page 1365)
3662
5
INJ (page 1365)
3663
4
INJ (page 1365)
3663
5
INJ (page 1365)
3664
4
INJ (page 1365)
3664
5
INJ (page 1365)
3695
2
AFT (page 156)
3695
19
AFT (page 156)
3703
31
AFT (page 156)
3713
31
AFT (page 156)
3719
0
AFT (page 156)
3719
15
AFT (page 156)
3719
16
AFT (page 156)
3750
31
AFT (page 156)
Condition Description
AFT Fuel Enable Control Valve short to PWR
AFT Fuel Enable Control Valve open or short to GND
VREF 1 voltage above maximum
VREF 1 voltage below minimum
VREF 2 voltage above maximum
VREF 2 voltage below minimum
VREF 3 voltage above maximum
VREF 3 voltage below minimum
Improper Reductant in DEF Tank
AFT Fuel Pressure 2 excessively high (Restricted injection)
AFT Fuel Pressure 2 below desired (Possible system leak)
AFT Fuel Injector not responding as expected
DPFOP signal erratic, intermittent or incorrect
DPFOP signal Out of Range HIGH
DPFOP signal Out of Range LOW
Injector 1 close coil – short circuit
Injector 1 close coil – open circuit
Injector 2 close coil – short circuit
Injector 2 close coil – open circuit
Injector 3 close coil – short circuit
Injector 3 close coil – open circuit
Injector 4 close coil: short circuit
Injector 4 close coil – open circuit
Injector 5 close coil – short circuit
Injector 5 close coil – open circuit
Injector 6 close coil – short circuit
Injector 6 close coil – open circuit
DPF Regen Inhibit Switch erratic, intermittent or incorrect
DPF Regen Inhibit Switch status not detected on J1939
DPF Active Regeneration Inhibited Due to Inhibit Switch
DPF Active Regeneration Inhibited Due to System Timeout
DPF Soot Load - Highest (level 3/3)
DPF Soot Load - Lowest (level 1/3)
DPF Soot Load - Moderate (level 2/3)
DPF Regen inhibited due to low exhaust temperatures