6. Sensors
6.1 Temperature sensors in district heating pipes
If the iGRID Pressure and Temperature Zone products have pre-
installed temperature sensors, make sure that the operating range
of the sensors corresponds to the expected operating temperature.
The temperature sensors are mounted in thermowells.
6.2 Pressure sensors in district heating pipes
If the iGRID Pressure and Temperature Zone products have pre-
installed pressure sensors, make sure that the operating range of
the sensors corresponds to the expected operating pressure.
6.3 Flow sensors in pipe connections
If the iGRID Pressure and Temperature Zone products have a pre-
installed flow sensor, make sure that the operating range of the
sensor corresponds to the expected flow.
10
7. Electrical connection
DANGER
Electric shock
Death or serious personal injury
‐
The system must be fitted with an external supply dis-
connecting device. Make sure that the supply discon-
necting device can be locked in the disconnected posi-
tion [OFF].
‐
If not supplied by Grundfos, the pumps must be indi-
vidually fitted with an external supply disconnecting
device.
DANGER
Electric shock
Death or serious personal injury
‐
In case of an insulation fault, the fault current may be
a DC or pulsating DC. Observe national legislation
about requirements for and selection of Residual Cur-
rent Device (RCD) when installing the pump.
‐
All electrical installations must comply with EN
60204-1 and local regulations.
‐
Do not make any constructional changes to the solu-
tion.
WARNING
Electric shock
Death or serious personal injury
‐
All electrical connections must be carried out by an au-
thorised electrician according to local regulations.
WARNING
Electric shock
Death or serious personal injury
‐
Follow the installation and operating instructions for
the pump or pumps and other electrical equipment.
WARNING
Electric shock
Death or serious personal injury
‐
Make sure that any control panels and internal pipe in-
stallations are connected to earth.
7.1 Routing of cables
WARNING
Electric shock
Death or serious personal injury
‐
Make sure that the cables do not touch hot surfaces.
The cables between the power box and the pump or pumps must
be routed in the pre-assembled cable trays or channels.
When installing or removing the pump, do not pinch or
damage the cables.