5 Technical Specifications

5.1 Power Supply Specifications

Power Supply
Type
12 – 24 VDC
10 VDC
24 VDC
18 VDC
48 VDC
36 VDC
HI (125/250 VDC)
1
88 VDC
HI (110/230 VAC)
1
85 VAC
Table 7: Power Supply Specifications
NOTES:
1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse
3. Power consumption varies based on configuration. 10/100Tx ports consume roughly 1W
less than fiber optic ports
4. For continued protection against risk of fire, replace only with same type and rating of fuse.

5.2 Failsafe Relay Contact Ratings

Parameter
Max Switching Voltage
Rated Switching Current
Max Switching Capacity
Table 8: Failsafe Relay Contact Ratings
©
2008 RuggedCom Inc. All rights reserved
All manuals and user guides at all-guides.com
Input Range
Rating
Min
Max
36 VDC
6.3A(F)
36 VDC
5A(F)
59 VDC
2A(T)
300 VDC
2A(T)
265 VAC
240VAC, 125VDC
2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC
150W, 500VA
29
Fuse
Max. Power Consumption
2
2
2
1,2
Value (Resistive Load)
3
15 W