Advertisement

Quick Links

SMART REVERSE OSMOSIS
UNIT
Installation &
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for DAYLIFF OSMOSIS

  • Page 1 SMART REVERSE OSMOSIS UNIT Installation & Operating Manual...
  • Page 3 INDEX SPECIFICATIONS 2. WARNINGS & SYMBOLS 3. INSTALLATION 4. OPERATION 5. MAINTENANCE 6. TROUBLE SHOOTING 7. TERMS OF WARRANTY © Davis & Shirtliff Ltd 2020 Contents herein are not warranted...
  • Page 4: Specifications

    • Output 1,800L/day, • Three stage sediment & carbon cartridge pre-treatment with easy to replace cartridges and LED replacement reminder. • Reverse osmosis purification using Hidrotek membranes with up to 50% recovery. • Post Carbon stage for water conditioning. • Supplied complete with 24VDC diaphragm pump •...
  • Page 5 Feed Water Temperature: 5~45℃ Feed-water TDS: ≤ 250ppm Feed-water Chlorine level: ≤ 0.2ppm Rejection: 90~99% Feed-Water Pressure: 0.1~0.4 Mpa Water Treatment Process Flow Diagram Technological Process Puried Water (Optional) Feed Water PP Filter GAC Filter CTO Filter Water Special Pump RO Filter T33 Filter Drain Water...
  • Page 6: Warnings And Symbols

    2. WARNINGS & SYMBOLS Wash and replace cartridges regularly. WARNING Do not disassemble parts randomly, it may cause leakage or damage. WARNING Do not use power supply with disproportional rated voltage. WARNING Please pull the power plug and cut off the feed water valve if long term storage.
  • Page 7: Installation

    Water hammer is a pressure surge or wave caused when water in motion is forced to step or change direction suddenly.When resident in building close his valve NOTE suddenly, a pressure wave propagates in the pipeline of building. 3. INSTALLATION Product and Accessories Main Body Six Filter Cartridges...
  • Page 8 Functional Schematic Diagram Tap water RO water faucet faucet Tap water pipe Puried Power water 3-way ball (optional) Drain water RO water pipe valve pipe (1/4" blue pipe) (1/4" red pipe) Inlet water pipe L e a v e a t l e a s t 1 0 0 m m (3/8"...
  • Page 9 Installation for Goose Faucet Ÿ Select a convenient location near your sink to place the faucet. Ÿ Drill a hole 12mm in diameter in counter top. Ÿ Place washers, plates, seals and nuts in order as per diagram and tighten on to counter.
  • Page 10 First Use Instruction 1. Connect RO system with adapter, then the power indicator light is on, buzzer rings three times, machine flushes for 90 seconds and indicator light is flashing in blue slowly. 2. RO system begins making water and indicator light is flashing in blue slowly, system is in standby mode and indicator light keeps in blue when water tank is full.
  • Page 11 1. Push side board according to arrow direction 2. Lift up cartridge 30°, rotate anticlockwise then remove it. 3. Install new cartridge by rotating clockwise according to specifications, then fix the side board.
  • Page 12: Troubleshooting

    Please reset cartridges after replacement NOTE 6. TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Insufficient feed water pressure Increase feed water pressure Water pump No power or power failure Power-on is out of High pressure switch is out of service and Replace high pressure switch order system does...
  • Page 13: Terms Of Warranty

    7. TERMS OF WARRANTY i) General Liability In lieu of any warranty, condition or liability implied by law, the liability of Dayliff in Ÿ respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Company’s discretion) defects which under proper use appear therein and arise solely from faulty design, materials or workmanship within a specified period.
  • Page 16 www.davisandshirtliff.com INS463A-09/20...

Table of Contents