Summary of Contents for DAYLIFF DC80D

  • Page 1 Engine Pumps DC80D DCX150P DC80P Installation & Operating Manual...
  • Page 3: Table Of Contents

    INDEX PUMP SPECIFICATIONS 2. SUCTION HOSE CONNECTIONS PUMP OPERATIONS ROUTINE MAINTENANCE SAFETY WARNINGS TROUBLE SHOOTING WARRANTY © Davis & Shirtliff Ltd 2015 Contents herein are not warranted...
  • Page 4: Pump Specifications

    Thank you for choosing Dayliff DC engine pump. Both pump and engine have been manufactured to the highest standards and if operated correctly should give many years of efficient and trouble free service. Careful reading of this instruction manual is therefore extremely important and if you have any queries please refer them to your retailer.
  • Page 5 DCI 80D FLOW (m /hr) The DAYLIFF DC range of self priming engines pumps are of fully portable design suitable for irrigation, dewatering and general pumping duties. All pump bodies and impellers are manufactured from high grade cast aluminium. Also included are quick-couple hose connectors and suction strainers.
  • Page 6: Suction Hose Connections

    Engine Dimensions (mm) Fuel Gross Inlet Fuel/ Max. weight Model & Star- Capacity Tank Consumption Type Power (kg) Outlet (cc) (ltr) (lt/hr) (HP) DC 50P 2” Petrol LT200P Kohler DC 50K 2” Petrol 1.96 Sh265 DC 80P 3” LT200P Petrol Kohler DC 80K 3”...
  • Page 7: Engine Oil

    3. PUMP OPERATION CHECK ENGINE OIL. Operating without oil will · Priming port cause severe engine damage and invalidate the warranty. Fill the pump chamber to overflowing with water · through the priming port. Insufficient water will cause pump damage and limit suction performance.
  • Page 8: Safety Warnings

    5. SAFETY WARNINGS Read and carefully understand the Instruction Manual before Instruction before use. Manual Avoid proximity to fire when refueling. Highly inflammable! Ensure good ventilation around the pump and do not operate indoors. Exhaust gases are very poisonous. Do not operate pump inside a well or pit. There will be an exhaust gas build up and the pump will overheat.
  • Page 9: Trouble Shooting

    6. TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Rusting inside engine Cannot pull or Overhaul Engine Engine jammed hard to pull Recoil starter Dismantle & clean the impeller Jammed Impeller Reduce delivery head Delivery head exceeds pump capacity Specify different pump Air leakage from suction side Check suction hose Output power down from engine...
  • Page 10: Warranty

    7. TERMS OF WARRANTY i) General Liability In lieu of any warranty, condition or liability implied by law, the liability of Davis & Shirtliff (hereafter called the Company) in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Company's discretion) defects which under proper use appear therein and arise solely from faulty design, materials or workmanship within a specified period.
  • Page 12 INS177E-07/15...

This manual is also suitable for:

Dc80pDcx150p