DAYLIFF DQ 15F Installation & Operating Manual

DAYLIFF DQ 15F Installation & Operating Manual

Circulator pumps

Advertisement

Quick Links

DQ
Circulator Pumps
DQ 15F
DQ 25/32
DQ 40/50/65
Installation &
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for DAYLIFF DQ 15F

  • Page 1 Circulator Pumps DQ 15F DQ 25/32 DQ 40/50/65 Installation & Operating Manual...
  • Page 2 INDEX PUMP SPECIFICATIONS 2. WARNINGS AND SYMBOLS 3. INSTALLATION OPERATION MAINTENANCE TROUBLE SHOOTING TERMS OF WARRANTY © Davis & Shirtliff Ltd 2020 Contents herein are not warranted...
  • Page 3: Pump Specifications

    Congratulations on selecting a Dayliff DQ Pump. They are manufactured to the highest standards and if installed and operated correctly will give many years of efcient and trouble free service. Careful reading of this Installation Manual is therefore important, though should there be any queries they should be referred to the equipment supplier.
  • Page 4 PUMP DAYLIFF DQ circulator pumps are designed for hot water circulation in heating, hot water, cooling and air conditioning applications in open or closed systems. They can also be used for pressure boosting in domestic dwellings and for circulation in solar hot water systems. Specifications are offered as follows;...
  • Page 5 PUMP DATA Dimensions (mm) Power Current Inlet/ Weight Model Outlet (kg) ¾” DQ 15F 0.55 105.5 1½” DQ 25/60 0.45 DQ 32/80 2” Dimensions (mm) Weight Model (kg) DQ40/100 1½” DQ50/120 1100 DQ65/110 1500 2½” 105.5 “ DQ 15F DQ 25/60...
  • Page 6: Warnings And Symbols

    2. WARNINGS AND SYMBOLS The pump must not be installed against wood or any other material which may be affected by heat from the pump. WARNING Before installing the pump ensure all soldering/welding adjacent to the pump is complete, the system has been thoroughly ushed out to remove any foreign matter and WARNING that vent and feed pipes are positioned so that the pump...
  • Page 7: Installation

    Ensure no water leakage onto the pump motor or its electrical connections during installations, venting or operation as this may cause electrical shocks. WARNING Any action that doesn’t comply with safety warning sign may cause personal injury, pump damage and losses in property.
  • Page 8: Operation

    After use, the Manual Restart knob, should be screwed back nger tight into its original position. NOTE Ensure no uid drips onto the pump motor or its electrical connections during installation, venting or operation as when the pump is energised this may create a risk of WARNING electric shock .
  • Page 9 Before switching the pump on, the manual restart should be unscrewed Ÿ and withdrawn to engage the motor shaft. Check that the shaft rotates freely and that the knob can be seen rotating on initial start up of the pump. Screw manual restart back in.
  • Page 10: Maintenance

    5. MAINTENANCE No routine maintenance is necessary, however, during prolonged shut Ÿ down it is advisable to run the pump for a few minutes every few weeks. Locked pump Should the pump fail to start, switch to maximum setting. If the pump still Ÿ...
  • Page 11: Terms Of Warranty

    7. TERMS OF WARRANTY i) General Liability In lieu of any warranty, condition or liability implied by law, the liability of Davis Ÿ & Shirtliff (hereafter called the Company) in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Company’s discretion) defects which under proper use appear therein and arise solely from faulty design, materials or workmanship within a specified period.
  • Page 12 INS341C-04/18...