  • Page 2: Table Of Contents

    INDEX PUMP SPECIFICATIONS 2. INSTALLATION ELECTRICAL CONNECTIONS MAINTENANCE SAFETY WARNINGS TROUBLE SHOOTING TERMS OF WARRANTY © Davis & Shirtliff Ltd 2014 Contents herein are not warranted...
  • Page 3: Pump Specifications

    Thank you for choosing Dayliff DDW drainage pump. The pump has been manufactured to the highest standards and if operated correctly should give many years of efficient and trouble free service. Careful reading of this instruction manual is therefore extremely important and if you have any queries please refer them to your retailer.
  • Page 4: Installation

    Pump (kg) Amps Outlet 0.75 DDW 750S 1¼” DDW 750V 0.75 1¼” 2. INSTALLATION The pump can be used for various drainage and water transfer installations for tanks, ponds and basements. It is best installed in a sump of minimum 40cm square and 50cm deep to allow for float switch operation.
  • Page 5: Electrical Connections

    3. ELECTRICAL CONNECTIONS The installer is responsible for making electrical connections to the mains supply in compliance with relevant local regulations. Ensure that a professional electrician carries out the electrical connections WARNING and that the following guidelines are followed:- All installations must be provided with an isolator to cut off mains power supply and coarse current protection in the form of a fuse or MCB rated at 2- 3 times the full load current as given on the pump plate.
  • Page 6: Trouble Shooting

    6. TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Check mains supply No mains supply Pump does not Check switch adjustment Level switch not switching on Low water level Clean suction (See Maintenance Pump suction sieve clogged section) Pump runs with no flow Check delivery hose &...
  • Page 7: Terms Of Warranty

    7. TERMS OF WARRANTY i) General Liability i) General Liability In lieu of any warranty, condition or liability implied by law, the liability of Davis & Shirtliff (hereafter called the Company) in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Company's discretion) defects which under proper use appear therein and arise solely from faulty design, materials or workmanship within a specified period.