DAYLIFF AQUASTRONG CIRC 16 Installation & Operating Manual

DAYLIFF AQUASTRONG CIRC 16 Installation & Operating Manual

Smart inline boosting pumps

Advertisement

Quick Links

AQUASTRONG CIRC 16
Smart Inline Boosting Pumps
Installation &
Operating Manual

Advertisement

Table of Contents
loading

Summary of Contents for DAYLIFF AQUASTRONG CIRC 16

  • Page 1 AQUASTRONG CIRC 16 Smart Inline Boosting Pumps Installation & Operating Manual...
  • Page 3 INDEX SPECIFICATIONS 2. WARNINGS & SYMBOLS 3. INSTALLATION APPLICATION OPERATION TROUBLE SHOOTING WARRANTY © Davis & Shirtliff Ltd 2021 Contents herein are not warranted...
  • Page 4: Specifications

    Congratulations on selecting Dayliff CIRC 16 Smart Inline Boosting Pump. They are manufactured to the highest standards and if installed and operated correctly will give many years of efcient and trouble free service. Careful reading of this Installation Manual is therefore important, though should there be any queries they should be referred to the equipment supplier.
  • Page 5 PUMP Dayliff Aquastrong CIRC 16 is a highly innovative smart inverter controlled water boosting pump suitable for various domestic applications including hot water circulation for electric or solar water heaters as well as shower and general tap pressure boosting. Particular features include:- •...
  • Page 6: Warnings And Symbols

    81mm 155mm 140mm 110mm Weight: 1.2Kg 2. WARNINGS AND SYMBOLS The pump must not be installed against wood or any other material which may be affected by heat from the pump. WARNING Before installing the pump ensure all soldering/welding adjacent to the pump is complete, the system has been thoroughly ushed out to remove any foreign matter and WARNING that vent and feed pipes are positioned so that the pump...
  • Page 7: Installation

    Non-approved replacement parts may not be used. WARNING Ensure no water leakage onto the pump motor or its electrical connections during installations, venting or operations as this may cause electrical shocks. WARNING Any action that doesn’t comply with safety warning sign may cause personal injury, pump damage and losses in property.
  • Page 8 Installation Arrangement The pump and the controller must be installed either horizontally or vertically. Angled installations are not allowed. WARNING 1. Mark the location according to the bolt holes of the pump bracket and punch holes in the wall. 242.5mm Dimension with lter 183.5mm Dimension without lter...
  • Page 9 Plug into power and pump starts to work Waterproof Connector 4. APPLICATION Water Heater Boosting Shower Shower Support Pressure Relief Valve Inlet Piping (cold water) Outlet Piping (Hot Water) Shower Hose Aquastrong Circ 16...
  • Page 10 Solar Water Heater Boosting Outlet Piping (Hot Water) Inlet Piping (Cold Water) Domestic Applications Shower Shower Support Shower Hose WHB Faucet WC Cistern Shower Boosting Boosting Boosting...
  • Page 11: Operation

    5. OPERATION Forced Start Switch LED Indicator On Ÿ The LED indicator light is always on when the pump is on automatic mode. Ÿ The LED indicator light flashes continuously when the pump is on forced start mode . Ÿ CIRC 16 will start and stop automatically due to inbuilt flow sensor. Ÿ...
  • Page 12: Troubleshooting

    6. TROUBLE SHOOTING LED Indicator Solutions Errors Main Problems Problem Light Overvoltage or LED Indicator Replace the controller Controller faulty Undervoltage flashes once LED Indicator Controller faulty Replace the controller Overcurrent flashes twice Impeller stuck due to Disassemble the pump debris and clean LED Indicator...
  • Page 13: Exploded Diagram

    EXPLODED DIAGRAM Parts Parts Rotor impeller assembly Ceramic washer Motor shaft Water flow switch...
  • Page 14: Terms Of Warranty

    7. TERMS OF WARRANTY i) General Liability • In lieu of any warranty, condition or liability implied by law, the liability of Dayliff (hereafter called the Distributor) in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Distributor’s discretion) defects which under proper use appear therein...
  • Page 16 INSXXXA-00/21...

Table of Contents