Extron electronics IPL T CR48 User Manual

Extron electronics IPL T CR48 User Manual

Ip link tools
Hide thumbs Also See for IPL T CR48:
Table of Contents

Advertisement

Quick Links

User's Manual
IPL T CR48
IP Link
Tools
®
68-738-05 Rev. B
11 08

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics IPL T CR48

  • Page 1 User’s Manual IPL T CR48 IP Link Tools ® 68-738-05 Rev. B 11 08...
  • Page 2 Safety Instructions • English This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment. This symbol is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
  • Page 3: Fcc Class A Notice

    安全须知 • 中文 这个符号提示用户该设备用户手册中 有重要的操作和维护说明。 这个符号警告用户该设备机壳内有暴 露的危险电压,有触电危险。 注意 阅读说明书 • 用 户 使 用 该 设 备 前 必 须 阅 读 并 理 解 所 有 安 全 和 使 用 说 明 。 保存说明书 • 用户应保存安全说明书以备将来使 用。 遵守警告 • 用户应遵守产品和用户指南上的所有安 全和操作说明。...
  • Page 4 This page has been intentionally left blank.
  • Page 5 Step 3 Attach the network (LAN) cable to the IPL T CR48 unit and to a host PC, switch, hub, or router. See Ethernet connection in chapter 3 for more information on this connection.
  • Page 6 Connect power cords and turn on the equipment in the following order: output devices (projector lift, screen lift, lights, etc.), IPL T CR48 interface, serial controller or computer (PC), then input devices (motion detector, alarms, photo eyes, etc.). Step 6 Configure the IPL T interface using the ARP command.
  • Page 7: Table Of Contents

    Configuring the Hardware PC configuration ... 3-4 IPL T CR48 interface configuration ... 3-4 Configuring the IPL T CR48 using the ARP command ... 3-5 Configuring the IPL T CR48 using direct PC connection ...3-7 Firmware upgrades ...3-8 Chapter Four • Communication and Control Ports Overview Contact closure input ports ...
  • Page 8 Included parts...A-4 Accessories ...A-4 Appendix B • Glossary Glossary ... B-2 All trademarks mentioned in this manual are the properties of their respective owners. IPL T CR48 • Table of Contents ... 4-24 ... 4-25 ...A-4 ... B-2 4-10 ...A-2...
  • Page 9: Chapter One • Introduction

    IPL T CR48 Chapter One Introduction About this Manual About the IPL T CR48 Interface Features...
  • Page 10: About This Manual

    Control Message Protocol) or Ping, and DHCP (Dynamic Host Configuration Protocol). The IPL T CR48 interface is 1U high and one quarter rack wide. It is rack-mountable, using either a VersaTools (#60-190-20) or a Universal 1U Rack Shelf (#60-190-01). It can also be mounted near a screen or projector lift.
  • Page 11 Choice of mounting options — Can be mounted near a screen or projector lift or on a rack shelf. Remote management — The IPL T CR48 allows you to remotely activate and deactivate projector lifts, screens, and lighting systems.
  • Page 12 Introduction, cont’d IPL T CR48 • Introduction...
  • Page 13: Installation And Operation

    IPL T CR48 Chapter Two Installation and Operation Installation Overview Mounting the IPL T CR48 Rear Panel Features and Cabling Operation...
  • Page 14: Installation Overview

    Installation and Operation Installation Overview To install and set up an IPL T CR48 relay control interface, follow these steps: Turn all of the equipment off. Make sure that the input devices (motion detectors, alarms, photo eyes, etc.), the IPL unit, the output devices (projector or screen lifts, etc.) and the serial controller are all turned off and disconnected from the power source.
  • Page 15 I P L IN P I P L L IN IN P Figure 2-2 — Mounting the interface on the standard shelf IPL T CR48 • Installation and Operation IP L IN P L IN IP L IN P L IN (2) 4-40 x 3/16"...
  • Page 16: Furniture Or Projector Mounting

    Installation and Operation, cont’d Furniture or projector mounting In addition to using the IPL T CR48 unit on a rack, it can also be furniture or projector mounted. Furniture mount or projector mount the interface using the optional mounting kit (Extron part...
  • Page 17: Rear Panel Features And Cabling

    Rear Panel Features and Cabling All connections, including power, input and output, and control, are on the back panel of the IPL T CR48 interface. 00-05-A6-00-00-01 POWER 0.5A Figure 2-4 — IPL T CR48 interface back panel Power Power connection — Plug the external 12 V power supply into this connector.
  • Page 18: Ethernet/Lan

    UID # — The unique User ID Number (MAC address) of the unit (for example, 00-05-A6-00-00-01). IPL T CR48 • Installation and Operation The two power cord wires must be kept separate while the power supply is plugged in. Remove power before continuing.
  • Page 19: Operation

    Check indicator LEDs on the PC/laptop, on the interface, and on the network hub/router, etc., to ensure that all devices are plugged in and communicating. The IPL T CR48 is ready to be configured (see chapter 3, “Connection and Configuration”).
  • Page 20: Front Panel Indicators

    Installation and Operation, cont’d Front panel indicators The front panel of the IPL T CR48 has several indicator LEDs which show the current status of communications to and from the unit. A reset button is also available from the front panel, in...
  • Page 21 2. Sets IP back to factory IP 3. Sets Subnet back to factory default 4. Sets Gateway back to factory default 5. Sets port mapping back to factory default 6. Turns DHCP off 7. Turns events off IPL T CR48 • Installation and Operation...
  • Page 22 (<1 second) press causes an absolute system reset back to factory default conditions. Nothing happens if the momentary press does not occur within 1 second. The power LED will blink four times in quick succession, confirming a Mode 5 reset. IPL T CR48 • Installation and Operation 2-10...
  • Page 23 IPL T CR48 Chapter Three Connection and Configuration Connecting the Hardware Configuring the Hardware...
  • Page 24: Connecting The Hardware

    Connection and Configuration Connecting the Hardware To connect the IPL T CR48 unit, connect the input and output devices to the unit using figure 3-1 as a guide. 0 .5 Extron IPL T CR48 Ethernet Relay Control Interface Figure 3-1 — IPL T CR48 connections...
  • Page 25: Relay Connections

    Relay connections The IPL T CR48 relay control interface can be connected to any device that can be activated by a relay closure. This allows the relay to be tied to devices such as lights (preset recall), projector lifts, screen or drape controllers, etc.
  • Page 26: Configuring The Hardware

    IPL T CR48 interface configuration When you power on the IPL T CR48 unit for the first time, there are two ways to set up the IP address: Use the ARP command method.
  • Page 27: Configuring The Ipl T Cr48 Using The Arp Command

    The ARP command tells your computer to associate the IPL T CR48 unit’s MAC address with the assigned IP address. You must then use Ping to access the IPL T CR48 unit, at which point the device server’s IP address will be reconfigured.
  • Page 28 After verifying that the change was successful, issue the arp –d command at the DOS prompt. For example: arp –d 10.13.170.15 will remove 10.13.170.15 from the arp table arp –d* to remove all static IP addresses from the arp table. IPL T CR48 • Connection and Configuration...
  • Page 29: Configuring The Ipl T Cr48 Using Direct Pc Connection

    Configuring the IPL T CR48 using direct PC connection This type of connection is used initially to connect to and configure the IPL T CR48 unit. The unit’s default settings (IP address, subnet mask, and (optional) administrator name and password) must be changed in order to use the unit on an intranet (LAN) or on the Internet (WAN).
  • Page 30: Firmware Upgrades

    Connection and Configuration, cont’d After configuring your IPL T CR48, repeat steps 3 and 4 and change your TCP/IP settings back to their original configuration. Firmware upgrades Firmware upgrades become available as improvements are made to the versatility and functionality of the IPL T CR48.
  • Page 31 IPL T CR48 Chapter Four Communication and Control Ports Overview Communication with the Interface Programmer’s Guide for the Telnet and Web Browser Device Control Troubleshooting...
  • Page 32: Ports Overview

    “on” or “off” directly. Event scripting allows an event script to turn the relays “on” or “off” based on the state of the four inputs on the IPL T CR48, or any other event script conditions. States of the relay ports are volatile; if a given relay port is “on”...
  • Page 33: Communication With The Interface

    Explorer, you must also have Microsoft Script (version 5.6 or higher). The PC used to access the Web server must have a connection in common with the IPL T CR48 interface. In other words, both the unit and the PC should be connected to your local intranet or Internet.
  • Page 34: Establishing Or Changing System Or Port Settings

    Establishing or changing system or port settings The System Settings screen is used to initially configure or change configuration of the IPL T CR48 interface. You may be required to change system settings if your network changes, or if port settings change as you add or change display devices or switchers.
  • Page 35: Setting And Changing Your PasswOrds

    4 characters and a maximum of 12 characters. Click the Submit button to enter the changes, or click the Cancel button to revert to previous settings. If fields are blank, no passwords have been assigned. IPL T CR48 • Communication and Control...
  • Page 36: Editing And Adding E-Mail Alerts

    Editing and adding e-mail alerts If you have created scheduled events or monitoring tasks on the IPL T CR48 interface, you can write an e-mail alert with a message corresponding to that event or task (e.g., a timer notification indicating it’s time to replace a projector light bulb).
  • Page 37: Sending An E-Mail Alert Through Telnet

    “Command/response table for Simple Instruction Set (SIS) commands” later in this chapter for specific command code. For example, the code for sending an alert from the 4th numeric mailbox would be Esc 4 SM} IPL T CR48 • Communication and Control...
  • Page 38: Upgrading The Firmware

    Communication and Control, cont’d Upgrading the firmware Firmware upgrades become available as improvements are made to the versatility and functionality of the IPL T CR48 interface. These upgrades are available for download from the Internet. To upgrade the firmware: Click Firmware Upgrade on the menu (on the left side of the window) and the Firmware Upgrade screen (figure 4-8) is displayed.
  • Page 39 Delete button of the next file. If you wish to delete all files, click the Delete All button. The file count will revert to 0 and all subsequent pages will be deleted. IPL T CR48 • Communication and Control...
  • Page 40: Programmer's Guide For The Telnet And Web Browser

    IPL T interface recognizes as valid, the responses that are returned to the host, a description of the command’s function, or the results of executing the command. IPL T CR48 • Communication and Control 4-10 For Web browsers: all non-alphanumeric characters...
  • Page 41: Symbol Definitions

    X% = On/off status: 0 = off/disable; 1 = on/enable X^ = Dirty status: 1 = RAM needs to be saved to Flash; 0 = RAM has been saved to Flash (OK to power off/reset) IPL T CR48 • Communication and Control 4-11...
  • Page 42 X3& = Event buffer offset: range = 0 - MaxBufferSize X3* = Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit) IPL T CR48 • Communication and Control 4-12 User password cannot be assigned if no administrator password exists and returns E14.
  • Page 43: Copyright Information

    X6$ = Time in seconds to keep sending the broadcast message (0-255, default 10) Zero (0) clears broadcast mode. Copyright information ]© COPYRIGHT 2003, EXTRON ELECTRONICS IPL T CR48, Vx.xx] Mon, 17 Feb 2003 11:27:33] The copyright message is displayed upon connecting to IP Link product via TCP/IP or Telnet.
  • Page 44: Password Information

    Error responses When the IPL T CR48 interface receives a valid command, it executes the command and sends a response to the host device. If the unit is unable to execute the command because the command contains invalid parameters, it returns an error response to the host.
  • Page 45 IPL T CR48 • Communication and Control 4-15...
  • Page 46 Communication and Control, cont’d IPL T CR48 • Communication and Control 4-16...
  • Page 47 IPL T CR48 • Communication and Control 4-17...
  • Page 48 Communication and Control, cont’d IPL T CR48 • Communication and Control 4-18...
  • Page 49 4-19 IPL T CR48 • Communication and Control...
  • Page 50 Communication and Control, cont’d 4-20 IPL T CR48 • Communication and Control...
  • Page 51 IPL T CR48 • Communication and Control 4-21...
  • Page 52 Communication and Control, cont’d 4-22 IPL T CR48 • Communication and Control...
  • Page 53 IPL T CR48 • Communication and Control 4-23...
  • Page 54: Device Control

    (The default IP address is 192.168.254.254, but it may have been changed in the setup or configuration process. If it was changed, use the new address.) Telnet defaults to port Figure 4-11— Telnet command prompt IPL T CR48 • Communication and Control 4-24...
  • Page 55: Troubleshooting

    Power connections Ensure that all devices are plugged in. Make sure that each device is receiving power. If the device is receiving power, the interface’s front panel power LEDs will light. IPL T CR48 • Communication and Control 4-25...
  • Page 56: Data Connections

    IP address is not known, use the direct PC connection method (see chapter 3, “Connection and Configuration”). IPL T CR48 • Communication and Control 4-26 mask (check with your system administrator). program which might block the IP address of the unit.
  • Page 57 IPL T CR48 A ppendix A Specifications, Part Numbers, and Accessories Specifications Part Numbers and Accessories...
  • Page 58: Specifications, Part Numbers, Accessories

    Power ... Supplied by an included external power External power supply ... 100 VAC to 240 VAC, 50/60 Hz, external; Power input requirements ... 12 VDC, 0.5 A IPL T CR48 • Specifications, Part Numbers, and Accessories autodetect IP, Telnet, HTTP, SMTP autodetected IP address = 192.168.254.254...
  • Page 59 Regulatory compliance Safety... CE, CUL, UL EMI/EMC ... CE, C-tick, FCC Class A, ICES, VCCI IPL T CR48 • Specifications, Part Numbers, and Accessories 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing kit, part #60-190-01 (RSU 129);...
  • Page 60: Part Numbers And Accessories

    IPL T CR48 User’s Manual Accessories Accessories 19” 1U VersaTools 19” 1U Universal Rack Shelf kit Under-desk mount kit Mini projection mount kit IPL T CR48 • Specifications, Part Numbers, and Accessories ® Rack Shelf kit ® Replacement part number 60-544-05...
  • Page 61: Appendix B • Glossary

    IPL T CR48 A ppendix B Glossary Glossary...
  • Page 62: Glossary

    When these contact points meet, it creates a complete circuit (e.g., ports 1-4 to ground on the IPL T CR48). Custom Web page is any file that can be loaded into an IPL box and served by the IPL’s internal Web server.
  • Page 63 Internet, a table (see ARP) relates the device’s IP address to its corresponding physical (MAC) address on the LAN. Pass-through allows control systems to work with the IPL and provides a link between two ports. IPL T CR48 • Glossary...
  • Page 64 URL encoding allows you to send information and commands to the unit to change its configuration or provide you with feedback. IPL T CR48 • Glossary...
  • Page 65 Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:...
  • Page 66 Extron USA - West Extron USA - East Headquarters +800.633.9876 +800.633.9876 Inside USA / Canada Only Inside USA / Canada Only +1.919.863.1794 +1.714.491.1500 +1.919.863.1797 FAX +1.714.491.1517 FAX Extron Europe Extron Asia +800.3987.6673 +800.7339.8766 Inside Europe Only Inside Asia Only +31.33.453.4040 +65.6383.4400 +31.33.453.4050 FAX +65.6383.4664 FAX...

This manual is also suitable for:

Ip link ipl t cr48

Table of Contents