Extron electronics MD Floor Box AAP Bracket Kit AAP 100 MD Installation Manual
Extron electronics MD Floor Box AAP Bracket Kit AAP 100 MD Installation Manual

Extron electronics MD Floor Box AAP Bracket Kit AAP 100 MD Installation Manual

Extron electronics network adapter installation guide

Advertisement

Extron AAP 100 and MAAP 100 Installation Guide
The following procedure is for mounting the AAP 100 and MAAP 100 panels
on hard surfaces (plywood, hardwood, etc.). For soft surfaces (particle
board, drywall, etc.), additional hardware such as anchors may be required
(not provided).
1.
Make a copy of the appropriate full size rough-in template. Cut out the
center portion of the template up to the dashed guidelines.
C For accurate sizing, copy the template at exactly 100%.
2.
Place the template in the desired location and mark the guidelines for
the opening on the surface.
3.
Carefully cut away the material inside the guidelines. Check the
opening size by placing the panel against the opening.
4.
Cable the AAP(s)/MAAP(s) and install them on the panel.
5.
Place the panel against the surface and mark the locations of the two
wall mounting holes on the surface.
6.
Remove the panel and drill 1/4" deep pilot holes (half the width of the
shaft of the screw) at the marked locations. Replace the panel.
7.
Use two 1/2" (1.3 cm) long, #6 flat headed wood screws (provided) to
fasten the panel directly onto the surface. Hand tighten the screws.

Product Dimensions

0.100
1.750
2 x 0.875
0.000
0.100
1.750
2 x 0.875
0.000
AAP 100 pnl.eps
MAAP 100 pnl.eps
68-837-01 Rev. B

Installation Templates

The dashed line indicates the
recommended cut-out area
for the installation surface.
The dashed line indicates the
recommended cut-out area
for the installation surface.
Extron USA - West
Extron USA - East
Headquarters
+800.633.9876
+800.633.9876
Inside USA / Canada Only
Inside USA / Canada Only
+1.919.863.1794
+1.714.491.1500
+1.919.863.1797 FAX
08 08
+1.714.491.1517 FAX
The dashed line indicates the
recommended cut-out area
for the installation surface.
1.5" H x 2.25" W
(3.8 cm H x 5.7 cm W)
The dashed line indicates the
recommended cut-out area
Template for
for the installation surface.
the MAAP 100
1.5" H x 2.25" W
(3.8 cm H x 5.7 cm W)
Template for
the MAAP 100
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 3.25" W
(4.45 cm H x 8.25 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 3.25" W
(4.45 cm H x 8.25 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 4.5" W
(4.45 cm H x 11.4 cm W)
The solid, outer line
represents the outside
edge of the panel.
1.75" H x 4.5" W
(4.45 cm H x 11.4 cm W)
Template for
1.5" H x 3.5" W
(3.8 cm H x 8.9 cm W)
the AAP 100
Template for
1.5" H x 3.5" W
(3.8 cm H x 8.9 cm W)
the AAP 100
Extron Europe
Extron Asia
Extron Japan
+800.3987.6673
+800.7339.8766
+81.3.3511.7655
Inside Europe Only
Inside Asia Only
+81.3.3511.7656 FAX
+31.33.453.4040
+65.6383.4400
+31.33.453.4050 FAX
+65.6383.4664 FAX
© 2008 Extron Electronics. All rights reserved.
Extron China
Extron Dubai
+400.883.1568
+971.4.2991800
Inside China Only
+971.4.2991880 FAX
+86.21.3760.1568
+86.21.3760.1566 FAX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MD Floor Box AAP Bracket Kit AAP 100 MD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Network adapter maap100Aap 100Maap 100

Table of Contents