Page 1
Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notification. A Crane Co. Company...
CROSS-SECTIONS & PARTS LISTS ..........8 - 9 WARRANTY & RETURNED GOODS ..........11 Other brand and product names are trademarks or registered trademarks of their respective holders. Deming® is a registered trademark of Crane Pumps & Systems, Inc. 1997, 8/06 Alteration Rights Reserved...
Crane Pumps & Systems, Inc. is not responsible for pressures. It is recommended that a high case temperature losses, injury, or death resulting from a failure to observe switch or pressure relief valve be installed on the pump body.
SERVICE CENTERS: For the location of the nearest Deming Service Center, check your Deming representative or Crane Pumps & Systems Service Department in Piqua, Ohio, telephone (937) 778-8947 or Crane Pumps & Systems Canada, Inc., Bramton, Ontario, (905) 457-6223.
2. PRIMING It is important that the suction and discharge pipes “line CAUTION: Before starting the pump, the casing and up” naturally with the pump. Do Not “pull” pipes into position with flange bolts or fittings. Both suction and suction line must be filled with liquid, and air-vented discharge pipes must be supported independently near through the vent pipe plugs.
D. MAINTENANCE i. Claen and carefully inspect all parts for wear or damage. Replace any part which is excessively worn or damaged. 1. LUBRICATION Motor bearings should have periodic attention and 2. REASSEMBLY lubrication in accord with motor manufacturer’s a. With adapter impeller face up, press seal seat gently recommendations.
F - LOCATING TROUBLE 1. No Liquid Delivered a. Pump not primed - See Priming b. Speed too low - Check motor speed and nameplate c. Discharge head too high d. Suction lift over 15 feet. Check with vacuum gauge. e.
Page 10
Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.
Need help?
Do you have a question about the DEMING 3112 Series and is the answer not in the manual?
Questions and answers