Nortel DMS-10 Series Quick Reference Manual page 58

Automatic message accounting transmitter style billing media converter ii
Hide thumbs Also See for DMS-10 Series:
Table of Contents

Advertisement

48
Error Control II Jumper PCA Replacement Procedure
Procedure 6
Error Control II Jumper PCA (NTM609xx) replacement
Step
9
Insert the spare Error Control II Jumper PCA in the B chassis
(slot 5), making sure it is fully seated.
10
Put faulty PCA in the empty electrostatic bag.
11
Apply power to standby chassis (B processor) by operation of
the +8 V dc red rocker switch on the power supply.
Wait for start-up activity to end and the message, Software
Loaded or S/W Loaded to print. For Turbo BMCs and Non-
Turbo BMCs equipped with 1 GB disk drives, wait for the CP
S/W Loaded message to print.
12
To clear any alarms on the standby processor. At the mainte-
nance terminal, enter:
>DOS S RSERR 00 (cr)
Alarms will stay clear on the standby processor if there are no
faults.
13
Place the active processor unit in PRIME mode. At the Switch
and Status Panel of the BMC:
a. Press the A/B Select Switch to B.
b. Make the O/P Mode Select Switch P.
c. Turn the Mode Switch to the right and release.
14
To clear any alarms on the active processor. At the mainte-
nance terminal, enter:
>RSERR 00 (cr)
Alarms will clear if there are no faults.
15
When all maintenance activities are complete, be sure to
replace the front panel of the BMC.
Carefully line up the four captive screws of the front panel with
their mounting holes. Tighten the captive screws; but do not
bear down.
The procedure is complete.