38 Disk Replacement Procedure
Procedure 3
Install replacement disk drive
Step
i.e., if DISK MODE is currently AO then type AP
if DISK MODE is currently BO then type BP.
Proper responses for 380 MB, 760 MB, 1 GB and 2 GB Turbo
disks and 1 GB Non-Turbo disks:
BACKUP STARTED
This may take minutes to hours depending on the disk size and
usage. Use the DISK USAGE command to check disk usage.
BACKUP COMPLETE
(or)
DISK MODE AP
If replacing a 380 MB, 760 MB, 1 GB or 2 GB Turbo disk or a
1 GB Non-Turbo disk and the response is DISK NOT FOR-
MATTED, go to step 10.
If the BMC (AMAT) is a 30 to 380 MB Non-Turbo system,
there will be no immediate response. Craftsperson on site
should observe disk LED activity.
If replacing a 380 MB Non-Turbo disk and the system responds
with DISK NOT INITIALIZED, go to step 7.
Otherwise, go to step 9.
7
Reinitialize the new disk. This is for 30 MB to 380 MB Non-
Turbo disk drives only.
CAUTION
These disk commands may cause a loss of data. Make sure
the operational disk drive is in an ONLY mode before enter-
ing the following commands.
Enter: (at the terminal)
>DISK INIT 1x (cr)
where: x - A for newly installed disk A
- B for newly installed disk B.
Proper response:
INIT COMPLETE
If the response is NO DISK PARAMETERS, go to step 11.
For 380MB disks, go to step 6.
8
This is for 30 MB to 140 MB disk drives only.
Enter in the defective track(s) from the disk manufacturer's
defect (bad track) list. Enter: (at the terminal)
>DISK DEFMAP x (cr)
where: x - A for newly installed disk A
- B for newly installed disk B.
297-6201-500
BMCA001 and up
Description
DISK MODE BP