3. Starter motor
• Connect the jumper lead 1 to the starter
relay terminals on the battery end and the
starter motor end.
• Check the starter motor operation.
4. Starter relay
• Disconnect the starter relay from the cou-
pler.
• Connect the jumper lead to the starter
relay and the battery terminals.
Battery positive terminal → pink 1
Battery negative terminal → green 2
Battery positive terminal → red/white 3
Battery negative terminal →
È 120 V-60 Hz
É 220 V-50 Hz, 230 V-50 Hz
• Connect the pocket tester (Ω × 1) to check
the starter relay terminals for continuity.
Tester positive probe → red 5
Tester negative probe → red 6
*
ELECTRIC STARTING SYSTEM
C0NTINUITY
SWL4060J
MOVES
green/yellow 4
CONTINUITY
4-12
DOES NOT MOVE
Repair and/or replace the starter motor.
WARNING
• A wire that is used as a jumper lead must
have the equivalent capacity or more as
that of the battery lead, otherwise the
jumper lead may burn.
• This check is likely to produce sparks, so
be sure that no flammable gas or fluid is
in the vicinity.
È
É
NO CONTINUITY
Replace the starter relay.
+
ELEC
SWL4060T
SWL4070T