• Pressing the appropriate LID numeric key (i.e., 2) and
the appropriate function key (i.e.,
access an item without having to scroll through all the
items in that category. Press
maintenance decision.
Edit Mode — Because the LID first displays items in Status
mode when it is powered up, the user must log on to the con-
nected CC6400 Controller and press the
switch to Edit mode.
While in Edit mode, the user can change the configuration
of items. For example, the user could change the value of an al-
gorithm's configuration decision.
NOTE: Not all items have configuration data. If the item
selected does not have configuration data, pressing the
key will have no effect. The LID will display
EXPN/EDIT
"No configuration."
Accessing Items in Edit Mode — The two ways to access
items in Edit mode are the same as in Status mode, except for
an additional step — pressing the
The user can access configuration data in Edit mode in two
ways:
• Pressing the appropriate function key (i.e.,
to access a category (i.e., alarms), pressing
and then continuing to press that key (
through all the items in that category (i.e., Limit Alarm,
FUNCTION
KEYS
OPERATIVE
KEYS
ALRM
) to directly
to display the first
ENTER
key to
EXPN/EDIT
key.
EXPN/EDIT
) once
ALRM
EXPN/EDIT
) to scroll
ALRM
OMNIZONE VPAC
12:00
02-06-04
EXPN
1
STAT
EDIT
4
SET
SCHD
7
NUMERIC KEYS
Fig. 5 — Local Interface Display (LID)
Set point Alarm, Discrete Alarm, First Out Alarm,
Runtime Alarm, and Number of Starts Alarm).
NOTE: Scrolling by repeatedly pressing the function key
displays the name of all the items in that category, whether
or not they are actually configured. Scrolling by pressing
the up or down arrow displays only the configured items
within that category.
• Pressing the appropriate LID numeric key (i.e., 2),
the appropriate function key (i.e.,
to directly access an item without having
EXPN/EDIT
to scroll through all the items in that category.
QUICK ACCESS IN EITHER STATUS OR EDIT
MODE — Use Table 6 as a reference to directly access
CC6400 Controller items using a LID in either Status or Edit
mods. For example, to access maintenance data for the AO —
Heating VAV algorithm, press
access configuration data for the AO (Analog Output) —
Heating VAV algorithm, press
and
. If the database consisted of two AO — Heating
ENTER
VAV algorithms, to access the second one, press
mal),
2 ALGO
,
,
EXPN/EDIT
TEST
2
3
SRVC
ALRM
5
6
HIST
ALGO
CLEAR
8
9
.
ENTER
0
9
), and
ALRM
,
, and
. To
6
ALGO
ENTER
,
,
6
ALGO
EXPN/EDIT
,
(deci-
6
.
, and
ENTER
.
FUNCTION
KEYS
OPERATIVE
KEYS
,