LEGEND AND NOTES FOR ALL 50BV WIRING DIAGRAMS
ALARM — Unit Alarm Relay (Critical Fault)
ALM-CM — Alarm/Warning Relay Common
AO
— Analog Output
AQUA
— Aquastat
BM
— Blower Motor
BPS_S — Fan Start/Stop Relay
(VFD Bypass Mode)
BR
— Blower Relay
BYPAS — VFD Bypass Control
CBR
— Circuit Breaker
CC
— Compressor Contactor
CDWF
— Condenser Waterflow Relay
CDWFS — Condenser Waterflow Switch
CLO
— Compressor Lockout Control
CMP
— Compressor Control Relay
COMPR — Compressor
CSMUX — Signal Multiplexer-Comp Status
DEHUM — External Dehumidification
DHS
— Duct High Static Limit Switch
DO
— Digital Output
DSP
— Duct Static Pressure Transducer
NOTES:
1. Partial wiring shown on both power and control diagrams.
2. Class 2 transformer TRANS-1 is wired into separate circuit. Do not interconnect other
3. Shielded wire shall have drain wire connected to VFD ground screw. The floating end
4. Shielded wire shall have drain wire connected to the control panel, adjacent to the
ECONO — Economizer Valve/Damper Control
EWT
— Entering Water Temp. Sensor
FLTS
— Filter Status Switch
FREEZ — Freeze Thermostat
(Water Economizer)
FRZ
— Freeze Thermostat (DX Circuit)
FSD
— Fire Alarm/Shutdown
GND
— Ground
HIR
— Heat Interlock Relay
HPS
— High Refrigerant Pressure Switch
HWV
— Hot Water Valve
LPS
— Low Refrigerant Pressure Switch
MA_RA — Mixed/Return Air Temp. Sensor
MBVR
— Motorized Ball Valve Relay
MSR
— Local/Remote Control Relays
OLR
— Compressor Motor Protector
PCB1
— Unit Control Board
PCB2,3 — I/O Expansion Board
PHASE — Phase/Rotation Monitor
PHASER— Phase Monitor Relay
RAT
— Return Air Thermostat
transformers or circuits; circuit separation or compressor transformers from low voltage
control panel transformers shall be maintained.
of the drain wire shall be insulated.
PCB. The floating end of the drain wire shall be insulated.
LEGEND
RESET
ROCC
SAT
SPT
SF
SPEED — 0-10 VDC Signal Isolator for VFD
SW
T
TB2
TRANS — Transformer
TRMCT — VAV Terminals Control
TRMOP — VAV Terminals Open
VENTR — Ventilation Output
VFD
WARN
37
— External Reset
— Remote Occupancy
— Supply Air Temp. Sensor
— Space/Zone Temperature Sensor
— Supply Fan Start/Stop Relay
— Switch
— Transformer
— Terminal Block for Field Connections
— Variable Frequency Drive
— Unit Warning Relay
(Non-Critical Fault)
Unit Wire
Field Wiring