DESCRIPTION
OMNIZONE::INTLK09: Condenser Pump
Discrete Output Point
Discrete Input Point 1
Discrete Input Point 2
Discrete Interlock
Input 1 Comparison
Input 2 Comparison
Off Persistence Time
On Persistence Time
Output Logic Type
Power on Delay
OMNIZONE::INTLK10: Tower Request
Discrete Output Point
Discrete Input Point 1
Discrete Input Point 2
Discrete Interlock
Input 1 Comparison
Input 2 Comparison
Off Persistence Time
On Persistence Time
Output Logic Type
Power on Delay
OMNIZONE::INTLK11: Compressor Cooling
Discrete Output Point
Discrete Input Point 1
Discrete Input Point 2
Discrete Interlock
Input 1 Comparison
Input 2 Comparison
Off Persistence Time
On Persistence Time
Output Logic Type
Power on Delay
OMNIZONE::LINK_01: Linkage/AOSS Schedule 01
Setpoint Bias
Setpoint Schedule
Adaptive Optimal Start
AO Start Enable
Building Insulation
Unoccupied 24hr Factor
Offset Low Value
Offset High Value
Sensor Group/SPT Sensor
Time Schedule
Outside Air Temp
NTFC Algorithm
Heating Algorithm
Supply Air Temp
Fan Status
Adaptive Optimal Stop
AO Stop Enable
Maximum Stop Time
Setpoint Bias
Power on Delay
Evacuation
Pressurization
OMNIZONE::LMALM01: Supply air Sensor
Monitored Input Point
Alarm Inhibit Point
Limit Check
Low Limit
High Limit
Enable Delay Time
Persistence Time
Hysteresis
Alarm Processor
Alarm Processing
Re-Alarm Interval
Alarm=1 or Alert=0
Alarm Level
Alarm Source
Alarm Routing
Alarm Description Index
Alarm Message - Part 1
Alarm Message - Part 2
Alarm Message - Part 3
Alarm Message - Part 4
Power on Delay
*Default values from factory.
NOTE: See CC6400 Comfort Controller Overview and Configuration Manual for configuration information.
Configuration Screens (cont)
VALUE*
PUMP
COOLOK
SENSDI00
On
Off
30
2
Normal
0
TOWER
COOLOK
SENSDI00
On
Off
30
2
Normal
0
COMPRES
COOLOK
FAN_CDWF
On
On
2
30
Normal
0
VOLT_I00
SETPT03
Disable
30
15
0
0
CTRLPT
OCCPC01
OAT
NTFC_00
HCVAV01
SAT
SF_SFS
Disable
60
2
0
EVAC
TRMOP
SAT
SENSDI00
25
150
15
10
5
Enable
0
1
1
5
11010000
7
0
55
UNITS
Name
Name
Name
Sns1Sta
Sns2Sta
sec
OffPrst
sec
OnPrst
LogType
sec
PowerUp
Name
Name
Name
Sns1Sta
Sns2Sta
sec
OffPrst
sec
OnPrst
LogType
sec
PowerUp
Name
Name
Name
Sns1Sta
Sns2Sta
sec
OffPrst
sec
OnPrst
LogType
sec
PowerUp
Name
Name
Enable
BldInsul
UnOccFct
^F
Value
^F
Value
Name
Name
Name
Name
Name
Name
Name
Enable
min
MaxStop
^F
SPBias
sec
PowerUp
Evacuate
Pressure
Name
Name
dF
LowLim
dF
HighLim
sec
DlyTim
sec
Persist
^F
Hyst
AlmProc
min
ReAlmTim
Type
AlmLevel
AlmSrc
AlmRtg
AlmDesc
Message
Message
Message
Message
sec
PowerUp
NAME