Automatic Run Test - Carrier OMNIZONE 50XJ064-104 Operating And Troubleshooting Manual

Indoor self-contained remote air-cooled and water-cooled, vav systems 18 to 100 nominal tons
Table of Contents

Advertisement

LID
NUM.
Algorithms
KEY
(ALGO)
1
AO—Adaptive Control
2
AO—Cooling CV
3
AO—Cooling VAV
4
AO—Fan Tracking
5
AO—Heating CV
6
AO—Heating VAV
7
AO—Humidity Control
8
AO—Mixed Air CV w/IAQ
9
AO—Mixed Air VAV w/IAQ
10
AO—Permissive Interlock
11
AO—Reset
12
AO—Shared Transducer
13
AO—Static Pressure
14
DO—Analog
15
DO—DX-Staging VAV
16
DO—Electric Heat CV
17
DO—Electric Heat VAV
18
DO—Enthalpy Comparison
19
DO—Interlock
20
DO—Lighting Control
21
DO—Permissive Interlock
22
DO—Pump Control
23
DO—Prop Thermo
24
DO—Prop Thermo 2 Pipe
25
DO—Prop Thermo 4 Pipe
26
DO—Staged Thermostat
27
DO—Staging Control
28
DO—Time Clock
29
DO—Time Clock w/Check
30
AOSS Schedule
31
Network Broadcast
32
Linkage/AOSS Schedule
33
NTFC w/Enthalpy Check
34
Sensor Group
35
WSM Air Source
36
WSM Cool Source
37
Custom Program
LEGEND
AO
— Analog Output
AOSS — Adaptive Optimal Start/Stop
CV
— Constant Volume
DO
— Digital Output
IAQ
— Indoor Air Quality
N/A
— Not Available
NTFC — Nighttime Free Cooling
VAV
— Variable Air Volume
WSM
— Water System Manager
Automatic Run Test —
programmed with an automatic run test that checks connection
and operation of major components. To perform the run test:
Verify that the control display (LID device/System Monitor)
interface cable is connected to internal jack on main controller;
that the fire alarm/shutdown switch input (FSD) has a factory
jumper or field input; that Bypass (if installed) is set in the
DRIVE position; and that the Local/Off/Remote switch is set to
the REMOTE position.
NOTE: When the Local/Off/Remote switch is in the
REMOTE position, the controller time schedule is pre-set
(from the factory) as unoccupied. This means that the unit
will not turn on until the run test is enabled. However, if the
controller schedule has already been modified in the field,
and the current time of day is occupied, then the supply fan
will start. The run test will shut the fan down when it
Table 6 — Quick Access Chart
Status
(STAT)
Hardware Points
Alarm History
Software Points
Analog Point Trace
Temperature Input
Discrete Point Trace
Milliamp Input
Consumable Channel
Custom Milliamp Input
Internal Consumable
Voltage Input
Runtime Channel
Custom Voltage Input
Sensed Discrete Input
Latched Discrete Input
Pulsed Discrete Input
Milliamp Output
Custom Milliamp Output
Voltage Output
Custom Voltage Output
Discrete Output
Stepper Motor Output
Discrete Software Point
Analog Software Point
Network Data Out
Network Data In
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
The 50BV,XJ unit controls are
LID FUNCTION KEYS
History
Service
(HIST)
(SRVC)
Function Definition
Channel Definition
System Definition
Setpoint Definition
Database Control
Comfort Controller
N/A
CCN Control
N/A
LID Preferences
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
NOTES:
1. To change from Edit mode to Status mode, press
EXPN/EDIT
again.
2. Not all available selections will have items to select in sublevels.
begins. The run test will complete and then the supply will
automatically restart.
NOTE: If the Local/Off/Remote switch is in the OFF posi-
tion, it is normal for the red alarm light on the display panel
to be lit, indicating that the unit is disabled.
NOTE: If the red light stays on when the switch is moved to
REMOTE, or if any other problems occur during the run
test, refer to the Troubleshooting section of this manual.
To perform the Run Test:
1. Turn unit power on.
The LID display will show the controller identifica-
tion, time and date (Fig. 5):
OMNIZONE VPAC
hh:mm mm-dd-yy
10
Alarm
Setup
(ALRM)
(SET)
Limit
Set Clock
Setpoint
Real Time Clock
Discrete
Controller Password
First out
N/A
Runtime
N/A
# of starts
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
CLEAR
Schedules
(SCHD)
Occupancy
Setpoint
Holiday
S/W Setpoint
Network Time
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
or press