Configuration Screens - Carrier OMNIZONE 50XJ064-104 Operating And Troubleshooting Manual

Indoor self-contained remote air-cooled and water-cooled, vav systems 18 to 100 nominal tons
Table of Contents

Advertisement

DESCRIPTION
OMNIZONE::CC6400:Controller Identification
Description:
Location:
Software Part Number:
Model Number:
Serial Number:
Reference Number:
OMNIZONE::ADAPT01: VAVRESET Software point con-
trol
Analog Output Point
Status Point
Time Schedule
Setpoint Schedule
Reset Point
Reset
Start Reset Value
Stop Reset Value
Control Point
PID_Master_Loop
Proportional Gain
Integral Gain
Derivative Gain
Disabled Output Value
Minimum Output Value
Maximum Output Value
Starting Value
Block Iteration Rate
Power on Delay
OMNIZONE::ADAPT02: Head Pressure control
Analog Output Point
Status Point
Time Schedule
Setpoint Schedule
Reset Point
Reset
Start Reset Value
Stop Reset Value
Control Point
PID_Master_Loop
Proportional Gain
Integral Gain
Derivative Gain
Disabled Output Value
Minimum Output Value
Maximum Output Value
Starting Value
Block Iteration Rate
Power on Delay
OMNIZONE::ADAPT03: Building Pressure Ctrl.
Analog Output Point
Status Point
Time Schedule
Setpoint Schedule
Reset Point
Reset
Start Reset Value
Stop Reset Value
Control Point
PID_Master_Loop
Proportional Gain
Integral Gain
Derivative Gain
Disabled Output Value
Minimum Output Value
Maximum Output Value
Starting Value
Block Iteration Rate
Power on Delay
OMNIZONE::ANCTL01: Supply Fan Status
Discrete Output Point
Sensor Group/SPT Sensor
Time Schedule
Setpoint Schedule
Analog
Hysteresis
Block Iteration Rate
Power on Delay
*Default values from factory.
NOTE: See CC6400 Comfort Controller Overview and Configuration Manual for configuation information.

Configuration Screens

VALUE*
OMNIZONE VPAC
Test Version 0.009
CEPP-130124-07
6400
Version 1.6
VAVRESET
COOLOK
LINK_01
SETPT02
TEMP_I00
-40
245
RESET
1
0
0
0
0
20
20
10
0
MVLV
HEAD
LINK_01
SETPT04
TEMP_I00
-40
245
PRES
-0.2
-0.1
-0.1
0
40
100
100
10
0
EXH
OKFAN
LINK_01
SETPT08
TEMP_I00
-40
245
BSP
-20
-10
0
0
0
100
40
10
0
SFS
DSP
OCCPC01
SETPT01
0
30
0
45
UNITS
DevDesc
Location
PartNum
ModelNum
SerialNo
RefNum
Name
Name
Name
Name
Name
dF
StrtRst
dF
StopRst
Name
KP
KI
KD
%
DsblOut
%
MinOut
%
MaxOut
%
StartVal
sec
BlkRate
sec
PowerUp
Name
Name
Name
Name
Name
PSIG
StrtRst
PSIG
StopRst
Name
KP
KI
KD
%
DsblOut
%
MinOut
%
MaxOut
%
StartVal
sec
BlkRate
sec
PowerUp
Name
Name
Name
Name
Name
ma
StrtRst
ma
StopRst
Name
KP
KI
KD
%
DsblOut
%
MinOut
%
MaxOut
%
StartVal
sec
BlkRate
sec
PowerUp
Name
Name
Name
Name
in H2O
Hyst
sec
BlkRate
sec
PowerUp
NAME