Timing/Dialing Codes

The timing/dialing code is comprised of six (6) digits in the following format—parameters A through F
are defined in the table below:
The factory default timing/dialing code is:
Parameter
Function Description
Talk/Listen Delay. Switching
A
time between talk and listen
modes (i.e. VOX switching time).
Call Length. Sets maximum
length of time the ETP-120
Series Call Station can be
connected to a call.
B
When disabled, a CPC (Calling
Party Control) disconnect pulse
(voltage drop at end of call),
busy signal, silence, or return to
dial tone will be required for
proper hang up.
Silence Time Out. Sets the
length of time a call will be
C
connected without any voice
transmission.
Dial Next Number Timer. Sets
the number of rings before the
D
ETP-120 Series Call Station
dials the next phone number in
the number list.
Dial Next Number on Busy.
When a busy is detected the
E
ETP-120 Series Call Station will
dial the next phone number in
the number list.
F
Not Used
Page 15 of 27
Copyright 2021 Talk-A-Phone, LLC • 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • info@talkaphone.com • www.talkaphone.com.
All prices and specifications are subject to change without notice. Talk-A-Phone, Talkaphone, bAlert, Scream Alert, WEBS, and WEBS Contact are registered trademarks of Talk-A-Phone,
LLC. All rights reserved. All other trademarks mentioned in this document or website are the property of their respective owners and does not imply or indicate any approval, endorsement,
sponsorship, or affiliation with such owners unless such approval, endorsement, sponsorship, or affiliation is expressly indicated.
Installation & Operation Manual
A B C D E F # 1 8
2 3 4 7 2 1 # 1 8
Values
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0 or 1
2, 3, 4, ... , 9
1
2
Always set to 1.
ETP-120 Series Phone
Definition
0.1 seconds
0.2 seconds
[Default]
0.3 seconds
0.4 seconds
0.5 seconds
0.6 seconds
0.7 seconds
0.8 seconds
0.9 seconds
Disabled
1 minute
2 minutes
3 minutes
[Default]
4 minutes
5 minutes
6 minutes
7 minutes
8 minutes
9 minutes
Disabled
10 seconds
20 seconds
30 seconds
40 seconds
[Default]
50 seconds
60 seconds
70 seconds
80 seconds
90 seconds
Disabled
Dials next number after 2, 3, 4, ... , 9
rings
[Default 7 rings]
Disabled
Enabled
[Default]
-