Page 1
Connect over Ethernet to H5000 CPU Websocket – (default is http//:192.168.0.2) 1. Go to System > Device list and select the appropriate channel – “H5000 Analog Channel x” 2. With HLA cal switch off and no load (V out = 0V) observe and record the value shown in the...
Page 2
3. Turn Cal switch on and record new value. Again this should read the Cal equivalent voltage if the HLA has been correctly set up.
Page 3
Analog Voltage 2 - Recorded “Cal” voltage from step 3. 7. Click on “Apply Values” 8. With Cal switch still on confirm that H5000 displays now read a “Forestay” value of the Cal equivalent load (in this example 2.88T) 9. Turn off Cal switch. System is now set up N.B.
Need help?
Do you have a question about the H5000 and is the answer not in the manual?
Questions and answers