9. Package Contents ···························································································· 8 10. System Features ···························································································· 9 11. First Time Setup ··························································································· 10 11.1 Download BMC Mini App software ·························································· 10 11.2 Placing the Device ·············································································· 10 11.3 Installing the Air Filter and Filter Cap ······················································ 11 11.4 Connecting to Power ···········································································...
M1 Mini User Manual V1.0 1. Symbols 1.1 Control Buttons Bluetooth Button Start/Stop Button 1.2 Device Symbols Follow Instructions for Use Operating Instructions Type BF Applied Part (mask) Class II (Double Insulated) AC Power DC Power IP22 ≥12.5 mm Diameter, Dripping (15º tilted)
Warnings, Cautions, and Important Tips appear throughout this manual as they apply. 3. Intended Use The M1 Mini Auto CPAP system is a CPAP (Continuous Positive Airway Pressure) device designed for the treatment of adult Obstructive Sleep Apnea (OSA) only, either in the hospital or at home.
M1 Mini User Manual V1.0 IMPORTANT! • Read and understand the entire user manual before operating this system. If you have any questions concerning the use of this system, contact your home care provider or health care professional. • The pictures in the user manual are only for reference, if they are different from the material object, the latter shall prevail.
M1 Mini User Manual V1.0 5. Specifications Device Size Dimensions: 159 mm × 66 mm × 72 mm Weight:< 400 g Product Use, Transport and Storage Operation Transport and Storage Temperature: 5°C to 35°C (41˚F to 95˚F) -25°C to 70°C (-13˚F to 158˚F) Humidity: ≤93% Non-condensing...
Page 7
M1 Mini User Manual V1.0 Sound Power Level <38 dB, when the device is working at the pressure of 10 hPa. Maximum Flow Test Pressures (hPa) Measured Pressure at the Patient Connection Port (hPa) Average Flow at the Patient Connection Port (L/min)
M1 Mini User Manual V1.0 6. Available Therapies The device delivers the following therapies: CPAP – Delivers Continuous Positive Airway Pressure; CPAP maintains a constant level of pressure throughout the breathing cycle. Auto – Delivers CPAP therapy and provides an air pressure no less than the prescribed one based on the patient’s needs.
M1 Mini User Manual V1.0 Standby State The state of the device when power is applied but the airflow is turned off. Means the time unit “minute”. Means the time unit “hour”. yy mm dd / mm dd yy / dd mm yy Means the date.
• This device should only be used with the mask and accessories manufactured or recommended by BMC or with those recommended by your prescribing physician. The use of inappropriate masks and accessories may affect the performance of the device and impair the effectiveness of therapy.
M1 Mini User Manual V1.0 10. System Features Fig. 10-1 Name Function Press this button to Start / Stop delivering air. Start/Stop Button The indicator light is white. Press this button to control Bluetooth status: When Bluetooth is off, press this button to turn on the Bluetooth Bluetooth function;...
An inlet for the DC power supply. 11. First Time Setup 11.1 Download BMC Mini App software Search and download BMC Mini App in the App store. Support Android platform and IOS platform. 11.2 Placing the Device Place the device on a firm, flat surface. The anti-skid pad installed at the bottom of the device is convenient for fixing the device.
M1 Mini User Manual V1.0 • To avoid explosion, this device must not be used in the presence of flammable gases (e.g. anesthetics). • Tobacco smoke may cause tar build-up within the device, leading to the malfunctioning of the device.
M1 Mini User Manual V1.0 WARNINGS! • The device is powered on for use when the power adapter is connected. The Button turns the blower On / Off. • Use of the device at an AC voltage beyond the stated range (see Section 5 “AC Power Consumption”) may damage the device or cause device failure.
BMC Mini App,click the bluetooth icon , and start to search the device, select the BMC Mini device (name is device serial number, please check the device nameplate information) in the device list for Bluetooth connection.If the bluetooth device is connected successfully,the bluetooth working status light of the main device will be kept on.
When the Ramp function is turned on, the pressure will gradually rise to the prescribed treatment pressure according to the preset ramp time from the initial pressure, so as to make the patient fall asleep easily. The BMC Mini App displays a real-time countdown of the remaining ramp time in minutes.
Take off the mask and headgear, press the Start / Stop Button or click on the icon in the BMC Mini App, and the device will stop delivering air. Disconnect the power adapter from the power outlet to power off the device.
But the patient can choose other suitable Mask Type Pillow; masks as well. When selecting masks other than the above Other three types of BMC masks, the patient can identify the masks as other. None/ Moisture It can be selected according to the moisture exchanger...
“Leak!!” will appear in BMC Mini App. If the voltage supplied by the power adapter is too low,the status Low Input light of device will flash. If the main device is connected with BMC Mini App by bluetooth, a prompt of “Low Input Voltage!!” will Voltage!! appear in BMC Mini App.
M1 Mini User Manual V1.0 15. Introduction of "Report" Users can select to view the usage reports generated in a certain day or a certain period of time according to your needs. Users can use shortcut keys to quickly query or customize the time period query..
M1 Mini User Manual V1.0 17. Software upgrading When there is a new version of BMC Mini app or device firmware, there will be a prompt when opening BMC Mini app. According to the prompt, the software and firmware can be upgraded.
M1 Mini User Manual V1.0 18.3 Cleaning the Tubing (1) Remove the tubing from the device and mask before cleaning. (2) Clean the tubing in warm water which contains washing liquid, and then rinse it in clean water thoroughly. (3) After cleaning, air-dry the tubing in a cool, well-ventilated area, and avoid direct sunlight.
• If the device is used when the atmospheric pressure is out of the stated range (See Section 5), the accuracy of the leakage alert will be affected. (1) Use the BMC carrying case to carry the device and accessories along with you. Do not put them in your checked baggage.
M1 Mini User Manual V1.0 22. Technical Support Please contact BMC directly if you need the circuit diagram of the device and the list of components for certain purposes such as maintenance or connection to other equipment. BMC will provide the circuit diagram and / or other technical documents in whole or in part according to your needs.
M1 Mini User Manual V1.0 24. Troubleshooting The table below lists common problems you may have with the device and possible solutions to those problems. If none of the corrective actions solve the problem, contact your home care provider. 24.1 Common Problems in Patients and Corresponding...
Page 26
M1 Mini User Manual V1.0 Problem Possible Cause Solution(s) Nasal, sinus, or Sinus middle Contact your physician ear pain inflammation immediately patient will feel uncomfortable when treatment pressure is higher It takes a maximum of four weeks Discomfort than 13 hPa. However, the to adapt to pressurized air.
M1 Mini User Manual V1.0 24.2 Common Problems in the Device and Corresponding Solutions Problem Possible Cause Solution(s) Take a few deep breaths with the The Auto On / Off feature is mask on, and the device will start enabled...
M1 Mini User Manual V1.0 25. EMC Requirements The cables must be provided by BMC. The information of each cable is as follows: Power adapter: 1800 mm ± 45 mm, unshielded Tubing: 1800 mm ±10%, unshielded Guidance and manufacturer's declaration - electromagnetic emissions The device is intended for use in the electromagnetic environment specified below.
Page 29
M1 Mini User Manual V1.0 Guidance and manufacturer's declaration - electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.
Page 30
M1 Mini User Manual V1.0 manufacturer and d is the 5240 recommended separation 5500 distance in meters (m). Field strengths from fixed transmitter, determined electromagnetic site survey, should be less than the compliance level in each frequency range. Interference may occur in...
(1) year for main unit and three (3) months for all accessories from the date of sale by BMC Medical Co., Ltd. to the dealer. If the product fails to perform in accordance with the product specifications, BMC Medical Co., Ltd. will repair or replace, at its option, the defective material or part.
Need help?
Do you have a question about the M1 Mini and is the answer not in the manual?
Questions and answers