Summary of Contents for 2VV DAPHNE Comfort

  • Page 1 DAPHNE Comfort INSTALLATION, COMMISSIONING AND OPERATION P02-0327-0915-00 H02-0328-0915-00 S02 - SAFE - 0813 - 00 3/3...
  • Page 2: Before Starting

    The assessment was conducted pursuant to harmonized European standards included in the relevant EC Declaration of Conformity. The current and full version of the EC Declaration of Conformity can be found at www.2vv.cz or in the enclosed CD.
  • Page 3: Unpacking The Unit

    Check that you have received the model ordered. Should the • DAPHNE Comfort delivered model differ from the one ordered, do not unpack the unit and notify the supplier immediately. After unpacking, check that the unit and the accessories are in •...
  • Page 4 DATUM: 1.10.2015 ČÍSLO ČÍSLO VERZE VERZE MĚŘÍTKO PROMÍTÁNÍ MĚŘÍTKO PROMÍTÁNÍ 2-312-S04955 2-312-S04955 1:10 1:10 2VV s.r.o., Poděbradská 289 2VV s.r.o., Poděbradská 289 CZ-530 09 PARDUBICE CZ-530 09 PARDUBICE 252,5 252,5 G 5/4" G 5/4" 505,4 505,4 HRDA1-050 402,5 402,5 163,5 163,5 G 5/4"...
  • Page 5: Technical Parameters

    5. TECHNICAL PARAMETERS Power Power con- con- Noise Noise Maxi- sump- sump- Fre- Max. Noise level level Duct Intake Qty. Ten- tion tion haust quen- Weight in 3 level at ex- diam- Model filter phase sion pre- filter power [kg] inlet haust eter...
  • Page 6: Installing The Unit

    6. INSTALLATION Required distance The unit is not designed to filter air containing combustible or flammable particles, chemical fumes, coarse dust, carbon, grease, poisons, bacteria, etc. ATTENTION The intake and exhaust vents must not be blocked by non- combustible material. •...
  • Page 7: Installing On A Wall

    Installing on a wall Dimensions of the wall bracket: (included) HRDA1-V015 / HRDA1-V030 HRDA1-V050 / HRDA1-V070 Measure the location appropriately. • Drill holes in the wall and fix the bracket included. • Fix the bracket appropriately with 4 M8x80 screws and washers.
  • Page 8: Installation In A Fitted Kitchen

    ISO 2768 - mK NÁZEV MATERIÁLU: TOLEROVÁNÍ: ISO 8015 PL-ZN-0,8 DRSNOST: ISO 1302 Ra ČÍSLO MATERIÁLU: KRESLIL: Martin Poslušný V 4-001-0010 DATUM: 12.8.2015 NÁZEV DAP-300-HOLDER SCHVÁLIL: Jaroslav Hubert DATUM: 12.8.2015 ČÍSLO VERZE MĚŘÍTKO PROMÍTÁNÍ 3-022-D10272 2VV s.r.o., Poděbradská 289 CZ-530 09 PARDUBICE...
  • Page 9: Connecting The Condensate Drain

    6. INSTALLATION The sink (SK-AKS3) can be installed directly on the unit. (not included) CONNECTING THE VENTILATION DUCTWORK Connect the ductwork to the outlet and seal the joint with a aluminium tape or a coupling. This will prevent the trans- mission of vibrations.
  • Page 10: Electric Installation And Wiring

    6. INSTALLATION Model Model HRDA1-V015 HRDA1-V030 = power = total current = frequency = power HRDA1-V050 = speed of ventilation = weight = number of phases = el. protection = air flow Ver = version Serial number YOU WILL NEED Sealing tape •...
  • Page 11 DATA 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 6. INSTALLATION 5 54 53 52 51 PRESENCE IN GND DEFROST EXTERNAL REC ERR FIRE BOOST 15VAC SENSOR HEAT PUMP ON/OFF CO2/RH/EXT IN GND 15VAC CO2/RH/EXT...
  • Page 12: Initial Commissioning

    Check the following before switching on the unit for the first time: That the unit is properly closed and all the outlets are connected to the ductwork. • That the electric connection matches the diagram, including earthing and protection of external circuits. •...
  • Page 13 UNIT SETTINGS Weekly mode Display settings Language settings Date and time Ventilation rate settings Required temperature Unit's time settings switch Touch a day to set ventilation modes Unit's service settings Back SETTING THE VENTILATION RATE Display required air flow Reduce or increase the Display current unit's air flow air flow...
  • Page 14 LANGUAGE SETTINGS SERVICE MENU Enter code 1616 to access the service menu DISPLAY SETTINGS 23 - User lock 25 - Factory reset Brightness when using Access selected menu 06 - Filter timer Brightness Scroll to select menu in stand-by mode MENU 01 - MODE NFC SETTINGS 23 - User lock...
  • Page 15 MENU 02 - HW SETTING MENU 08 - AQS SENSOR 25 - Factory reset 06 - Filter timer 08 - AQS Sensor 06 - Filter timer 09 - Temperature sensor 08 - AQS Sensor 10 - Supply Duct Limits Select air You can choose the quality contact to switch the...
  • Page 16 MENU 10 - SUPPLY DUCT LIMITS MENU 12 - FLOW OFFSET 08 - AQS Sensor 10 - Supply Duct Limits 09 - Temperature sensor 11 - Bypass Temperature 10 - Supply Duct Limits 12 - Flow Offset 11 - Bypass Temperature 13 - Fire Flow 12 - Flow Offset 14 - Occupancy...
  • Page 17 MENU 14 - OCCUPANCY MENU 16 - FREECOOLING The FIRE FLOW and OCCUPANCY modes can not be used simultaneously 14 - Occupancy 15 - Boost 16 - Freecooling 17 - PID parameters 18 - HW test 12 - Flow Offset 13 - Fire Flow 14 - Occupancy 15 - Boost...
  • Page 18 MENU 18 - HW TEST 16 - Freecooling 17 - PID parameters 18 - HW test 20 - Modbus RTU 21 - Network The MODBUS menu is used to set the Modbus communication. MENU 21 - NETWORK 18 - HW test 20 - Modbus RTU 21 - Network 23 - User lock...
  • Page 19: Maintenance

    User security level Numeric password to unlock Several security levels can be chosen for possible password-free Pressing FACTORY RESET resets the unit is reset to its operation: factory settings ON/OFF - to turn the unit on or off without password It does not change: - The configuration of the AQS type ON/OFF, Temp., Flow - to turn the unit on or off, set the required - The ventilation mode...
  • Page 20: Error Messages

    Clean the unit with a vacuum cleaner, a small brush, cloth and soapy water, especially the exchanger. Do not use the following product to clean the unit: Sharp objects, corrosive chemicals, solvents, abrasive cleaners, pressurized water, pressurized air or steam. ERROR MESSAGES Clogged filter •...
  • Page 21: Troubleshooting

    9. TROUBLESHOOTING The unit error is indicated with a red exclamation mark in the middle of the control display Pressing the exclamation mark shows the information on the error, see table below Reports on the display Unit's behavior Likely problem SOLUTION Check that the air is flowing freely through the unit, that the 1 –...
  • Page 22 9. TROUBLESHOOTING REPAIRING OVERHEATED ELECTRIC PREHEATING AND REHEATING ATTENTION! The service of internal components must be done only by a professional. Always disconnect the unit before servicing. Firstly, remove the cause of the overheated electric preheating and reheating. • For easier access to the electric preheating and reheating, the filters and fans can be removed. •...
  • Page 23: Spare Parts

    10. SPARE PARTS Descrip- Unit code Number of parts in Spare part code Description Unit code Number of parts in Spare part code tion the unit the unit HRDA1-015UXCBE75-ES0X-0A0 HRDA1-015UXCBE75-ES0X-0A0 HRDA1-015UXCBE75-ES0B-0A0 HRDA1-015UXCBE75-ES0B-0A0 HRDA1-030UXCBE75-ES0X-0A0 Engine ND-DAP-150-S-VENT Servo 230V ND-SERVO-TD-04-230-1-M HRDA1-015UXCBE75-ES1C-0A0 HRDA1-030UXCBE75-ES0B-0A0 HRDA1-015UXCBE75-EE1C-0A0 HRDA1-050UXCBE75-ES0X-0A0 HRDA1-050UXCBE75-ES0B-0A0...
  • Page 24 10. SPARE PARTS Description Unit code Number of parts in Spare part code Description Unit code Number of parts in Spare part code the unit the unit HRDA1-015UXCBE75-ES1C-0A0 HRDA1-015UXCBE75-EE1C-0A0 HRDA1-050UXCBE75-ES0X-0A0 HRDA1-030UXCBE75-ES1C-0A0 Electric HRDA1-050UXCBE75-ES0B-0A0 Transformer TRAFO-230-24-15-12V ND-DAP-500-PRED HRDA1-030UXCBE75-EE1C-0A0 preheater HRDA1-050UXCBE75-ES1C-0A0 HRDA1-050UXCBE75-ES1C-0A0 HRDA1-050UXCBE75-EE1C-0A0 HRDA1-050UXCBE75-EE1C-0A0 HRDA1-015UXCBE75-ES1C-0A0...
  • Page 25 Once the it has been installed, read carefully the safe operation manual of the unit. That manual includes examples of possible problems and recommended solutions. In case of any requests or inquiries, contact our sales or technical department. Contact Address 2VV, s.r.o., Poděbradská 289, 530 09 Pardubice, Czech Republic Internet http://www.2vv.cz/contact.distribution.php...