Rectifying faults

Resetting welding parameters to the factory settings

Error
Possible cause
32
Electronics error (I>0 error)
33
Electronics error (Uact error)
34
Electronics error (A/D channel error)
35
Electronics error (slope error)
36
Electronics error (S sign)
37
Electronics error (temperature error) Allow the machine to cool.
38
---
39
Electronics error (secondary overvol-
tage)
40
Electronics error (I>0 error)
48
Ignition error
49
Arc interruption
51
Error in the emergency stop circuit
(interface for automated welding)
57
Auxiliary drive error, tacho error
59
Incompatible component
6.3
Resetting welding parameters to the factory settings
All customised welding parameters that are stored will be replaced by the factory settings.
To reset the welding parameters or machine settings to the factory settings, select parameter
service menu
6.4

Display machine control software version

The query of the software versions only serves to inform the authorised service staff. It is available in the
machine configuration menu > see 5.7 chapter.
66
> see 5.7 chapter.
Remedy
Switch the machine off and on. If the error persists, no-
tify Service.
Switch the machine off and on.
If the error persists, notify Service.
Inform service.
Check the welding process.
Inform service.
Check the external shutdown devices. Check jumper
JP 1 on PCB T320/1.
Check the auxiliary drive (tacho – no signal, M3.51 de-
fective > notify Service).
Replace component.
in the
099-00T401-EW501
01.02.2022