5.1.10.2 RTF response
This function controls the current response during the main current phase. The user can choose between
linear and logarithmic response. The logarithmic setting is especially suited for welding with low currents,
e.g. for thin panels, as the logarithmic response enables a better control of the welding current.
In the machine configuration menu, the RTF response function
response
and logarithmic response
099-00T401-EW501
01.02.2022
Functional characteristics
can be toggled between linear
(ex works) > see 5.7 chapter.
Figure 5-29
TIG welding