Display
099-00T401-EW501
01.02.2022
Setting/selection
TIG antistick > see 5.1.6 chapter
-------function active (factory setting).
-------function inactive.
Show warnings > see 6.1 chapter
-------Function disabled (ex works)
-------Function enabled
Setting the system of units
-------Units of length in mm, m/min. (metric system)
-------Unit of length in inches, ipm (imperial system)
Machine configuration (second part)
Settings for machine functions and parameter display
RTF start ramp > see 5.1.10.1 chapter
-------Welding current rises to the specified main current level in a ramp function (ex
works)
-------Welding current immediately jumps to the specified main current level
RTF response > see 5.1.10.2 chapter
-------Linear response
-------Logarithmic responsive (ex works)
Tungsten balling with RT AC remote control
-------Function disabled
-------Function enabled (in addition, the "AC balance" rotary knob at the RT AC re-
mote control has to be turned to the left stop) (ex works)
Welding current polarity switching
-------polarity switching at the RT PWS 1 19POL remote control (ex works)
-------polarity switching at the welding machine control
spotmatic operating mode > see 5.1.4.5 chapter
Ignition by contact with the workpiece
-------Function enabled (ex works)
-------Function disabled
Spot time setting > see 5.1.4.5 chapter
-------Short spot time, setting range 5 ms to 999 ms, increments of 1 ms (ex works)
-------Long spot time, setting range 0.01 s to 20.0 s, increments of 10 ms (ex works)
Process activation setting > see 5.1.4.5 chapter
-------Separate process activation (ex works)
-------Permanent process activation
Torch cooling mode
-------Automatic operation (ex works)
-------Permanently enabled
-------Permanently disabled
Welding torch cooling, post-flow time
Setting 1–60 min. (ex works 5 min.)
Time-based power-saving mode > see 5.4 chapter
Time to activation of the power-saving mode in case of inactivity.
Setting
= disabled or numerical value 5-60 min..
Operating mode switching via interface for automated welding
------Non-latched
-------Special non-latched
Re-ignition after arc interruption > see 5.1.3.3 chapter
-------JOB-dependent time (ex works 5 s).
-------Function disabled or numerical value 0.1–5.0 s.
Expert menu
Functional characteristics
Machine configuration menu