5.3.5.3

3-cycle operation

This operating mode differs from non-latched operation in the following ways:
Once the third cycle (current) has started, the wire electrode is fed, corresponding to the welding cur-
rent, until the welding process ends.
5.3.5.4

Latched mode

This operating mode differs from non-latched operation in the following ways:
Wire feeding is started by pressing and releasing (tapping) the BRT 1.
By pressing and releasing (tapping) the BRT 1 again, wire feeding will stop. (It is not necessary to
keep the torch trigger pressed. This is especially helpful with long welding seams.)
5.4

Power-saving mode (Standby)

You can activate the power-saving mode by either pressing the push-button > see 4 chapter for a prolon-
ged time or by setting a parameter in the machine configuration menu (time-controlled power-saving
mode
) > see 5.7 chapter.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. turning a rotary knob) deactivates power-saving mode and the ma-
chine is ready for welding again.
099-00T401-EW501
01.02.2022
Functional characteristics
Figure 5-44
Figure 5-45
Power-saving mode (Standby)