1). Signal level input connector
Connect to the Antenna or Coax cable. Maximum input Voltage is 5 Volts.
2). Frequency counter input
Connect to the signal source to be measured. Maximum input voltage is 5 Volts.
3). Volume control
Audio output Volume control. To increase the volume, rotate the Volume control clockwise.
4). Earphone Jack
5). Attenuator
" " (Pushed in) Inserts 10dB of attenuation into the Signal level input. Used in the presence
of noise or very strong signals.
" " (Pushed Out) No attenuation
6). LCD (Liquid Crystal Display)
Displays the Signal levels, their characteristics (frequency, amplitude, etc) and pertinent system
data.
7).
POWER
Press this button to turn the power on. Press again to turn the power off.
8).
KEY
LCD
Press the
LCD
Contrast control, LCD Grid select, Backlight and Print command. These items are
displayed when the
9).
MENU
Pressing the
MENU
again displays the System Menu items and pressing the
LCD to the signal level displays.