Mounting And Wiring - Ei Electronics aico Ei146e User Instructions

Hide thumbs Also See for aico Ei146e:
Table of Contents

Advertisement

ATTENTION:
Alternative Energy Sources - (Wind, Solar, UPS etc.)
This product is designed to be connected to a Pure or True Sine
Wave 230V AC supply.
If connecting to a power source that utilises an inverter, e.g. PV
solar panel, the Total Harmonic Distortion (THD) must be less
than 5%. If in doubt please check with the manufacturer of the
inverter.
This also applies to battery powered UPS (Uninterruptible Power
Supply) inverters.
Light Dimmer Circuits – The Alarms must not be powered from
a light dimmer circuit.
IMPORTANT PRECAUTION: Do not install Alarms in new or
renovated buildings until all work is completed.
The Alarm must not be connected when the house wiring
insulation is being checked with high voltages. i.e. Do not use a
high voltage insulation tester on the Alarm.
ATTENTION: The Alarm must be continuously powered 24 hours
a day so it is important that it is not on a circuit that can be
turned off by a switch.
WARNING: Electrical installations must comply with local
regulations.
WARNING: An all-pole mains switch shall be incorporated in the
electrical installation of the building.
WARNING: Always test the Alarm after battery replacement
and only use recommended 9V Alkaline battery. Do not expose
battery to excessive heat such as sunshine, fire, etc...

Mounting and Wiring

Disconnect the AC mains supply from the circuit that is going
to be used.
WARNING: to prevent injury, this apparatus must be securely
attached to the ceiling or wall in accordance with the installation
instructions.
Foam ceiling gasket
(must be in place)
Figure 1
Insert screwdriver
to lift and remove
wiring cover
5