Ei Electronics RadioLINK Ei170RF User Instructions
Ei Electronics RadioLINK Ei170RF User Instructions

Ei Electronics RadioLINK Ei170RF User Instructions

Strobe & vibration pad module for use with radiollnk smoke/heat/fire alarm s
Hide thumbs Also See for RadioLINK Ei170RF:

Advertisement

Quick Links

Professional
Model : EI17OR F
RadioLi N
Strobe & Vibration Pad Modul e
For use with RadioLlNK Smoke/Heat/Fire Alarm s
(Smoke / Heat / Fire Alarm
supplied separately)
Note : At least one RadioLlNK Smoke/Fire/Heat Alarm is required to make the .Ei17ORF
Alarm operational . This is not supplied with the Ei170RF and must be obtained separately .
Important : Read these instructions, together with those from the separate RadioLlN K
Smoke/Heat/Fire alarms and accessories before installation . All instruction leaflets must be
left with the end user after installation .

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RadioLINK Ei170RF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ei Electronics RadioLINK Ei170RF

  • Page 1 Model : EI17OR F Professional RadioLi N Strobe & Vibration Pad Modul e For use with RadioLlNK Smoke/Heat/Fire Alarm s (Smoke / Heat / Fire Alarm supplied separately) Note : At least one RadioLlNK Smoke/Fire/Heat Alarm is required to make the .Ei17ORF Alarm operational .
  • Page 2 The Ei170RF is for use with the following Ei RadioLINK Smoke/Fire/Heat Alarms and Accessories . Mains Multisensor/Smoke/Heat/Fire Alarms : Ei2110, Ei160RC & Eli 40 Series Alarms in conjunction with an Ei168RC RadioLINK Base . attery Powered Smoke / Heat Alarms : Ei3100RF, Ei3103RF, Ei3105RF, Ei405, Ei405TY, Ei605C (with RF module), Ei605TYC (with RF module) .
  • Page 3 Figure 2 Plug the battery into the socket at the rear of the battery compartment as shown in Figure 2 (whil e holding the small latch on the battery plug, open) . Place the battery in the compartment ensuring th e notch in the battery is used to leave clearance for the plug and sockets (see Figure 3) .
  • Page 4 Ifconnectingto a mains Junction Box It is preferable to permanently wire the unit into a mains junction box . In this case remove th e plug and wire as follows . Warning : If the plug is being removed and the unit is being wired to a junction box it should b e installed by a qualified .
  • Page 5 Clock Inpu t (if required) Main s Indicator Gree n (main s disconnected = amber flash/ 4 seconds) Alarm Figure 4 3.1 .6 If some units flash less than the expected number of times, after being in House Code Mode fo r over 10 minutes) (say four times on a six unit system) they are out of range of each other .
  • Page 6 4.1 AFTER INSTALLATIO N 4.1 .1 Check that all RadioLINK Alarms and Accessories are powered correctly . 4.1 .2 Check that the green light on the Ei17ORF Strobe Module is continuously lit . 4.1 .3 Press the test button on all RadioLINKED Smoke/Heat/Fire Alarms, Remote Controls an d Manual Call Points in turn, and check that all other Smoke/Heat/Fire Alarms in the system alarm afte r about 4 seconds and that the strobe and vibration pad activate .
  • Page 7 the battery will need to be replaced . Contact the nearest address in this leaflet for advice about gettin g a replacement. The battery also needs to be replaced if it is over 5 years old (see "replace battery by " date on side panel) .
  • Page 8 Drill Holes Her e Figure 5 Ei Electronics guarantees this device for five years from the date of purchase against any defects tha t are due to faulty materials or workmanship . This guarantee only applies to normal conditions of use an d service, and does not include damage resulting from accident, neglect, misuse, unauthorise d dismantling, or contamination howsoever caused .