Device Connected, But Not Ready; Start Unit Request Failed - Acer Altos 900 User Manual

Table of Contents

Advertisement

4. In the SCSISelect Advanced Configuration Options menu, set Extended BIOS -
Translation to Enabled.
5. Partition the drive again.
6. Restore data to the drive, if necessary.
4.6.1

Device connected, but not ready.

This message appears if the SCSI controller receives no answer when it requests
data from an installed SCSI device. The SCSI controller skips this device and
moves on to the next device on the bus.
Do the following if you see this message when you request data from a SCSI
drive:
1. Run the SCSISelect utility and access SCSI Device Configuration. Locate the
host controller's SCSI ID and set Send Start Unit Command to yes.
2. Exit the SCSISelect utility and request data from the drive again.
3. If the message still appears, follow the drive manufacturer's instructions to
make sure the drive is set to spin-up when the power is switched ON.
4.6.2

Start unit request failed.

The BIOS was unable to send a Start Unit Command to the device. Run the
SCSISelect utility and disable Send Start Unit Command for the device.
Time-out failure during SCSI Inquiry command!
or
Time-out failure during SCSI Test Unit Ready command!
or
Time-out failure during Start Unit command!