Mitsubishi Electric SS Series Manual page 13

Electronic multi-measuring instrument

Advertisement

■Standards Compliance
Electromagnetic Compatibility
Emissions
Radiated Emission
Conducted Emission
Harmonics Measurement
Flicker Meter Measurement
Immunity
Electrostatic discharge Immunity
Radio Frequency Electromagnetic field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Conducted Disturbances、 Induced By Radio Frequency Fields Immunity
Power Frequency Magnetic Field Immunity
Voltage Dips and Short Interruptions
Safety
Europe
U.S. and Canada
Installation Category
Measuring Category
Pollution Degree
■Notes Regarding MODBUS
Item
Interface
Protocol
Transmission method
Connection type
Baud rate
Data bit
Stop bit
Parity
Address
Distance
Max. connectable units
Terminal Resistance
Recommended Cable
■Notes Regarding CC-Link Communication
Item
No. of occupied stations
CC-Link version
Baud rate
Transmission method
Synchronous method
Encoding method
Transmission path format
Transmission format
Error control system
Number of connectable units
Remote station Number
■ For CC-Link connection cables, please use the dedicated cables.
For information regarding dedicated cables, please refer to the CC-Link Partner Product Catalog published by the CC-Link Partner Association or CC-Link
Partner Product Information on the CC-Link Partner Association website (http://www.cc-link.org).
Notes 1. Dedicated CC-Link cables compatible with Ver. 1.00 cannot be used in tandem with dedicated CC-Link high-performance cables compatible
with Ver. 1.00.
Notes 2. In the case of systems consisting of units compatible with Ver. 1.00, 1.10 or 2.00 used in tandem with Ver. 1.00 or 1.10 cables, Ver. 1.00
specifications will apply for the maximum total cable length and length of cables between stations.
Notes 3. For terminal resistance, be sure to use 110 Ω ±5% (1/2W product) when using dedicated CC-Link cables or 130 Ω ±5% (1/2W product) when
using dedicated CC-Link high-performance cables.
■ Option Specifications
Item
Analog output
4-20mA (0~600 Ω)
No-voltage "a" contact Capacity: 35VDC,
Pulse/Alarm output
0.1A
Digital input
19-30VDC 7mA or less
Digital output
No-voltage a contact Capacity: 35VDC, 0.2A ME-0052-SS96
CE、 as per EN61010-1
cRUus as per UL61010-1、 IEC61010-1
2
RTU Communication
®
RS-485 2-wire half-duplex transmission
RTU mode
Asynchronous
Multi-point bus
2,400/4,800/9,600/19,200/38,400bps
8
1 or 2
Odd, even, none
1 to 255 (0:for broadcast mode)
1,200m (max)
31 units
120 Ω 1/2W
Shielded twisted-pair AWG24 to 14
1 Station Remote device station
CC-Link Ver 1.10/Ver 2.00
10Mbps/5Mbps/2.5Mbps/625kbps/156kbps
Broadcast polling system
Frame synchronous system
NRZI
Bus format (EIA RS485)
HDLC
CRC (X
16
+ X
12
+ X
5
+ 1)
42 units (max, remote device station)
1 to 64
Specification
ME-4210-SS96
ME-4210-SS96
ME-4210-SS96,ME-0040C-SS96,ME-0052-SS96
EN61326-1/CISPR 11,
FCC Part15 Subpart B Class A
EN61326-1/CISPR 11
FCC Part15 Subpart B Class A
EN61000-3-2
EN61000-3-3
EN61326-1/EN61000-4-2
EN61326-1/EN61000-4-3
EN61326-1/EN61000-4-4
EN61326-1/EN61000-4-5
EN61326-1/EN61000-4-6
EN61326-1/EN61000-4-8
EN61326-1/EN61000-4-11
Specifications
Specifications
Optional Plug-in Module type
12