Crane Barnes 10 ICU-1 Installation And Operation Manual

Self-priming centrifugal pumps, universal drive

Advertisement

Quick Links

INSTALLATION and OPERATION MANUAL
Self-Priming Centrifugal Pumps
IMPORTANT!
Read all instructions in this manual before operating pump.
As a result of Crane Pumps & Systems, Inc., constant product improvement program,
product changes may occur. As such Crane Pumps & Systems reserves the right to
change product without prior written notification.
A Crane Co. Company
420 Third Street
Piqua, Ohio 45356
Phone: (937) 778-8947
Fax: (937) 773-7157
www.cranepumps.com
BARNES
BARNES
83 West Drive, Bramton
Ontario, Canada L6T 2J6
Phone: (905) 457-6223
Fax: (905) 457-2650
®
Universal Drive
Models:
10 ICU-1
Form No. 033825-Rev. N

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Barnes 10 ICU-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Crane Barnes 10 ICU-1

  • Page 1 Read all instructions in this manual before operating pump. As a result of Crane Pumps & Systems, Inc., constant product improvement program, product changes may occur. As such Crane Pumps & Systems reserves the right to change product without prior written notification. A Crane Co. Company...
  • Page 2: Table Of Contents

    START-UP REPORT ..................15 - 18 WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders. ® Barnes is a registered trademark of Crane Pumps & Systems, Inc 1984, 2002, 2003, 4/06, 8/06 Alteration Rights Reserved...
  • Page 3: Safety First

    It is recommended that a high case temperature switch or pressure relief valve be installed on the pump body. IMPORTANT! - Crane Pumps & Systems, Inc. is not responsible for losses, injury, or death resulting from a CAUTION! Pumps build up heat and pressure...
  • Page 4: Pump Specifications

    SECTION: A - PUMP SPECIFICATIONS SUCTION/DISCHARGE . 2” x 2” NPT, Female BEARING - PUMP END LIQUID TEMP ....160°F (71°C) Continuous Design ..Single Row, Ball INTERMEDIATE ..... Cast Iron ASTM A-48, Class 30 Lubrication..Grease VOLUTE ......Cast Iron ASTM A-48, Class 30 Load .....
  • Page 5: General Information

    For the location of the nearest Barnes Service Center, check seal assembly. The seal assembly is filled at the factory but your Barnes representative or Crane Pumps & Systems, Inc. must be checked for proper fill before the pump is put into Service Department in Piqua, Ohio, telephone (937) 778-8947 service.
  • Page 6: Operation

    D-4) Restart: At each subsequent start, particularly if the pump has been drained, the priming liquid level should be checked since the pump is self-priming only when the body is full of liquid. SECTION E: PUMP SERVICE AND REPAIR: E-1) Check Valve Service: To clean out or repair check valve, disconnect suction piping.
  • Page 7: Replacement Parts

    E-4) Pedestal and Shaft Service: To examine or replace shaft (1) or pedestal (2), disassemble as outlined in Paragraph E-2 and E-3. Remove slinger (3), cap screws (5), lockwashers (6) and pull bearing cap (28) together with shims (27). Remove shaft with assembled bearings. Examine all parts and replace those showing wear or damage.
  • Page 8: Trouble Shooting

    TROUBLE SHOOTING CAUTION ! Always disconnect the pump from the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. SYMPTOM POSSIBLE CAUSE(S) Little or no discharge 1. Casing not filled with water 1.
  • Page 11: Parts List

    PARTS KIT Seal Kit .... P/N: 085238 (†) 3, 4, 9, 10, 11, 13, 14, 17, 22b, 35, 36 Overhaul Kit ..P/N: 085239 () 3, 4, 5, 7, 8, 9, 10, 11, 13, 14, 16, 17, 20, 22b, 27, 29, 35, 36 ITEM QTY.
  • Page 12: Returned Goods Policy

    Crane Pumps & Systems, Inc. Distributor. RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A “RETURNED GOODS AUTHORIZATION”. CONTACT YOUR LOCAL CRANE PUMPS & SYSTEMS, INC. DISTRIBUTOR. Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment, To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material.

Table of Contents