Working with a Recalled Video
5– To recall a saved video file, navigate to the saved file via the File Manager. Select the video (which will have an mp4 file extension). The video will
automatically replay.
6
– These soft keys control the video while it is playing. Use the joystick to rewind or fast-forward the video.
Capturing a Still Image from Video
7
– Click here to freeze the video action at any time. Once frozen, the screen image can be saved.
8
- Use the joystick left or right to quickly select previous or subsequent Chapters.
Using External Video
To use external video, simply connect the external video source to the capture device. Then connect the capture device to an MViQ via USB(a) port.
Once connected, external video will be used in place of probe video anytime the video capture device is connected.
Measuring Features and Indications
About Measuring
The MViQ allows you to measure features or indications either before or after saving an image. You can save up to five measurements per image. In order
to perform 3D Phase Measurements (3DPM) or stereo measurements, the image must be captured using a 3DPM, or stereo tip. All saved measurement
images can be re-measured on a PC using Inspection Manager software from Waygate Technologies. For details, call your local sales representative.
You can save measurement images as JPEGs or bitmaps. You can view these files, including the measurement results, in most .BMP or .JPG viewing ap-
plications, such as Windows Paint
Notes:
-Measurement results are valid only when taken in air. To measure through liquid, contact Waygate Technologies.
-Waygate Technologies cannot guarantee the accuracy of measurements calculated by the MViQ system. Accuracy varies with the application and
the operator's ability.
-The MViQ system can display measurement images that were captured on the Everest XLG3™ and XLGo VideoProbe systems, including their previously
captured measurements. However, we do not support re-measurement of images captured with systems other than the MViQ.
-Measurement image data must not be altered or compressed to remain viable for post inspection remeasurement.
-For more information on Real3D Measurement, please reference the Real3D
TM
Measurement Handbook.
55