Supplying Power to the MViQ
The MViQ is powered by a 10.8 V (nominal), 73 Wh, 6.8 Ah Lithium Ion battery.
The battery is charged by connecting the power adaptor to the battery, then
connecting the supplied AC-to-DC power adaptor to a suitable (100-240
VAC, 50-60 Hz, <1.5 A rms) AC power source. The power adaptor delivers to
the battery 18 Volts at 3.34 Amps.
Note: When powering a system with an AC power source, connect the power
plug to a properly grounded source for reliable touchscreen operation.

Powering the MViQ On and Off

System Power On
Press and hold
until the unit turns on. The buttons and Liquid
Crystal Display (LCD) will light and begin the power-up sequence. After
approximately 1 minute, the system screen will display live video and on-
screen controls. The system is now ready for use.
Note: All batteries are shipped with a partial charge. Batteries should be
fully charged prior to use.
System Power Off
Touch the lower left corner of the display screen (which typically contains
1
the on-screen Logo (
) or the
hard key at any time to open or close
the Global Menu, which provides access to several features including Shut
2
Down (
). Select Shut Down to power off the MViQ.
Caution—Do not power off the MViQ by removing its battery. Only
remove battery after powering off as described above.