WARNING!
This appliance is manufactured with
the frame grounded by connection of a
grounding strap between the neutral power
supply terminal and the frame. If used in
USA, in a new branch circuit installation
(1996 NEC), mobile home or recreational
vehicle, where local code do not permit
grounding through neutral (white) wire
or in Canada; remove the grounding strap
from the frame and cut the other end, near
the neutral terminal. Connect the appliance
in usual manner.
Three Conductor Wire Connection to Range
If local codes permit connection of the frame
grounding conductor to the neutral wire of the
copper power supply cord (see Figure 8):
1. Remove the screws from the access plate at
the lower right end of the rear cover to expose
range terminal connection block.
2. Using the nuts supplied in the literature
package, connect the neutral of the copper
power supply cord to the center silver-colored
terminal of the terminal block, and connect the
other wires to the outer terminals. Match wires
and terminals by color (red wires connected
to the right terminal, black wires connected to
the left terminal) (see Figure 8).
3. Replace the terminal cover and replace the
screws.
Terminal
Block
Black
Wire
A User Supplied
To 240 V
Strain-relief Must
Receptacle
Be Installed at
This Location.
Figure 8
8
Silver Colored
Grounding
Terminal
Strap
Cord
Mounting
Plate
Neutral
(White Wire)
1 1/8" (2.9 cm)
Dia. Direct
Connection Hole.
Punch Out Knockout
for 1 3/8" (3.5 cm)
Dia. Cord Kit Hole.
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of
the frame grounding conductor to the neutral wire
of the copper power supply cord (see Figure 9):
1. Remove the screws from the access plate at
the lower right end of the rear cover to expose
range terminal connection block.
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature
package, connect the ground wire (green) of
the copper power supply cord to the frame of
the appliance with the ground screw, using the
hole in the frame where the ground strap was
removed (see Figure 9).
4. Connect the neutral of the copper power
supply cord to the center silver-colored
terminal of the terminal block, and connect the
other wires to the outer terminals. Match wires
and terminals by color (red wires connected
to the right terminal, black wires connected to
the left terminal).
5. Replace the terminal cover and replace the
screws.
Terminal Block
Black
Wire
1 1/8" (2.9cm)
Dia. Direct
Connection
Hole. Punch Out
Red
Knockout for 1
Wire
3/8" (3.5cm) Dia.
Cord Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
NOTE: Be sure to remove the
supplied grounding strap.
Silver Colored
Terminal
Red Wire
Neutral
(White Wire)
To 240 V Receptacle
Figure 9
Ground
(Bare
Copper
Wire)
AA-2282381-1